Vermont Casting 36XDV User Manual

Page of 56
10009383
7
XDV Direct Vent Gas Fireplace
    
 
 
Max. 
Min.
    
 
 
Input 
Input
  Model 
Fuel  Gas Control  BTU/h  BTU/h
  33XDVRN 
Nat.  Millivolt Hi/Lo  21,500  4,400
  33XDVRP 
Prop.  Millivolt Hi/Lo  21,500  5,425
  33XDVEN 
Nat.  24 Volt Hi/Lo  21,500  4,400
  33XDVEP 
Prop.  24 Volt Hi/Lo  21,500  5,425
  36XDVRN 
Nat.  Millivolt Hi/Lo  27,500  5,150
  36XDVRP 
Prop.  Millivolt Hi/Lo  27,500  5,500
  36XDVRFN  Nat.  Comfort Contrl  27,500  5,810
  36XDVRFP  Prop.  Comfort Contrl  27,500  6,225
  36XDVEN 
Nat.  24 Volt Hi/Lo  27,500  5,150
  36XDVEP 
Prop.  24 Volt Hi/Lo  27,500  5,500
  39XDVRN 
Nat.  Millivolt Hi/Lo  30,000  6,700
  39XDVRP 
Prop.  Millivolt Hi/Lo  30,000  5,800
  39XDVEN 
Nat 
24 Volt Hi/Lo  30,000  6,700
  39XDVEP 
Prop  24 Volt Hi/Lo  30,000  5,800
Framing and Finishing 
Check fireplace to make sure it is levelled 
and properly positioned.
To mount the appliance:
1.  Choose the location.
2.  This unit comes with four (4) flanges pre-mounted 
on both sides of the fireplace to allow two different 
drywall thicknesses to be used. Flange “A” is for 
1/2” drywall while flange “B” is for 5/8” drywall.
3.  Bend the desired flanges out 90° on both sides of 
the fireplace. Slide the fireplace into the framed 
opening until the flanges contact the front surfaces 
of the framing. Level the unit and secure it firmly in  
place.
Fig. 5  Nailing flanges.
 
Flange 
Drywall
  Position 
Depth
 
1/2” / 13 mm
 
5/8” / 16 mm
Flange Location for 
Desired Drywall Depth
FP1539
Noncombustible materials such as brick or tile may be 
extended over the edges of the face of the fireplace. 
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the 
brick or tile will have to be installed flush with the edges 
of the fireplace.
Final Finishing
33XDV / 36XDV / 39XDV
Certified To
ANSI Z21.88-2005 / CSA  2.33-2005
Vented Gas Fireplace Heaters
Gas Specifications
  Inlet Minimum 
5.5” w.c. 
11.0” w.c.
  Inlet Maximum 
14.0” w.c. 
14.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.
Gas Inlet and Manifold Pressures
 
Natural 
LP (Propane)
High Elevations
Input ratings are shown in BTU per hour and are 
certified without deration for elevations up to 
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA, 
installations must be in accordance with the cur-
rent ANSI Z223.1/NFPA 54 and/or local codes hav-
ing jurisdiction.
In Canada, please consult provincial and/or local 
authorities having jurisdiction for installations at 
elevations above 4,500 feet (1,370m).
Gas Line Installation
When purging the gas lines, the front win-
dow frame assembly must be removed.
The gas pipeline can be brought in through the rear 
of the appliance as well as the bottom. Knockouts are 
provided on the bottom behind the valve to allow for the 
gas pipe installation and testing of any gas connection. 
It is most convenient to bring the gas line in from the 
rear right side of the valve as this allows fan installation 
or removal without disconnecting the gas line.
A
B
FP1539a
flanges w/standoffs
5/05
Units: GFDN3L1, GFDE3L1, GFDN3J1, GFDI3J1, 
GFDE3JI, GFDN3K1, GFDE3K1