Lennox Hearth MPDR-3328CNE-B User Manual

Page of 42
25
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LENNOX HEARTH PRODUCTS  •  MERIT
®
 PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45)  •  INSTALLATION INSTRUCTIONS
Step 5. FIELd WIRING
TP-TH
TP
TH
APPLIANCE- MOUNTED
ON/OFF SWITCH
(OPTIONAL)
BK/W(1)
BK/W(1)
WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)
THERMOSTAT (OPTIONAL)
JUNCTION BOX
BLACK
W
GR
120 V AC
WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)
BK
R
WIRING DIAGRAM MILLIVOLT GAS VALVES
THERMOPILE
GAS VALVE
FAN
(OPTIONAL)
Figure 47
       
CAUTION
The  ground  supply  lead  must  be 
connected to the wire attached to the 
green ground screw located on the  
outlet box (see wiring diagrams)
Failure  to  do  so  will  result  in  a 
potential  safety hazard. The appli-
ance must be electrically grounded 
in accordance with local codes or, 
in the absence of local codes, the 
National  Electrical  Code,  ANSI/
NFPA 70-latest edition (in Canada, 
the  current  CSA  C22-1  Canadian 
Electrical Code).
CAUTION:  Label all wires prior to discon-
nection  when  servicing  controls.  Wiring 
errors can cause improper and dangerous 
operation. 
ATTENTION:  Au moment de l’entretien 
des commandes, étiquetez tous les fils 
avant de les débrancher.  des erreurs 
de cáblage peuvent entraîner un fonc-
tionnement inadéquat et dangereux.
Verify proper operation after servicing.
S’assurer que l’appareil fonctionne adé-
quatement une fois l'entretien terminé.
1. If any of the original wire as supplied must be replaced,
1.  
it must be replaced with
 
Type AWM 105
°C – 18 GA. wire.
2. 120V, 60Hz – Less than 3 amps.
BK
Transf.
120 V.
24 V
Factory Wired
Field Wired
BL
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
FBK-250 Kits
R
WH
BL
W
Gas Valve
B
R
IGNITER
BK
Schematic Representation Only
*ON/OFF Switch (Integral
with Gas Valve)
Optional
FBK-250
Module
*Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
G
OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH
 OR OPTIONAL WALL SWITCH OR OPTIONAL THERMOSTAT
OR OPTIONAL REMOTE RECEIVER
PILOT
ASSEMBLY
OPT
BLOWER
Junction Box
White
Green
Red
Black
Neutral
Side of
Receptacle
Tab Intact
Green
Ground
Screw
Hot
Side of
Receptacle
Tab
Broken
Optional
Accessory
Switch
120 VAC - Black
n
e
e
r
G
-
d
n
u
o
r
G
e
ti
h
W
-
l
a
rt
u
e
N
1. If any of the original wire as supplied must be replaced,
1.  
it must be replaced with
 
Type AWM 105
°C – 18 GA. wire.
2. 120V, 60Hz – Less than 3 amps.
BK
Transf.
120 V.
24 V
Factory Wired
Field Wired
BL
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
FBK-100 and FBK-200 Kits
R
W
BL
W
Gas Valve
B
R
IGNITER
BK
*Blower speed control switch is provided in FBK200 blower kit.
Schematic Representation Only
**ON/OFF Switch (Integral
with Gas Valve)
**Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH
 OR OPTIONAL WALL SWITCH
OR OPTIONAL THERMOSTAT
OR OPTIONAL REMOTE RECEIVER
G
OPT
BLOWER
PILOT
ASSEMBLY
Junction Box
White
Green
Red
Black
Neutral
Side of
Receptacle
Tab Intact
Green
Ground
Screw
Hot
Side of
Receptacle
Tab
Broken
120 VAC - Black
n
e
e
r
G
-
d
n
u
o
r
G
Optional
Accessory
Switch
e
ti
h
W
-
l
a
rt
u
e
N
Figure 49
Figure 48
Refer to Section A for millivolt appliances and 
Section  B  for  electronic  appliances.  The  gas 
valve is set in place and pre-wired at the factory 
on both models.
A. Millivolt Wiring
 (see Figure 47)
Millivolt  units  are  not  provided  with  any 
factory-installed controls; therefore, one of the 
optional control switches is required to operate 
the unit (ON/OFF Wall Switch, Unit-Mountable 
ON/OFF Switch*, Thermostat, Remote Control). 
See the fireplace Care and Operation Instruc-
tions for details.
[*If using a Unit-Mountable ON/OFF Rocker Switch 
with an optional Style View Door, mount the Rocker 
Switch on the door instead of the unit.]
1.  If installing an ON/OFF wall switch or ther-
mostat, mount it in a convenient location on 
a wall near the fireplace.
2.  Wire the control switch within the millivolt 
control circuit using the 15 feet of 2 con-
ductor wire supplied with the unit.
  Note: The supplied 15 feet of 2 conductor 
wire has one end of each conductor con-
nected to the gas valve circuit and the other 
end of each conductor placed loose inside 
the bottom compartment.
 CAUTION
In millivolt systems, do NOT connect 
a Wall Switch to a 120V power supply.
B. Electronic Wiring
 (see Figures 48 & 49)  
The electronic gas valve has an integrated ON/
OFF burner control switch. One of the follow-
ing optional controls also may be used: ON/
OFF Wall Switch, Thermostat, Remote Control 
(see fireplace Care and Operation Instructions 
for details.).
Note: Electronic models must be connected to 
the main power supply.
1.  Route  a  3-wire  120Vac  60Hz  1ph  power 
supply to the appliance junction box.
2.  Remove the electrical inlet cover plate from 
the side of the unit by removing the plate’s 
securing screws (see Figure 13, Page 11).
3.  Remove the cover plate knockout; then feed 
the power supply wire through the knockout 
opening and into the unit junction box.
4.  See  Figures  48  &  49.  Connect  the  black 
power supply wire to the lower outlet’s red 
pigtail lead
  Connect the white power supply wire to the 
outlet’s common terminal
5.  Connect  the  ground  supply  wire  to  the 
pigtail lead attached to the outlet’s green 
ground screw.