NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LENNOX HEARTH PRODUCTS  •  MERIT
®
 PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45)  •  INSTALLATION INSTRUCTIONS
Note:  Remote receiver should be  located in the 
wall, or if installed in the control compartment, 
pulled all the way forward and completely to the 
left or right against the corner posts.  
6. If wall-mounted ON/OFF control or thermo-
stat is to be used, mount it in a convenient 
location on a wall near the fireplace.
7.  If an optional control is to be used, wire it in 
the low voltage circuit as shown in Figures 
48 and 49.
Note: The supplied 15 feet of 2 conductor wire 
has one end of each conductor connected to 
the gas valve circuit and the other end of each 
conductor  placed  loose  inside  the  bottom 
compartment.
8.  If  the  optional  control  switch  is  installed, 
turn the appliance-mounted ON/OFF burner 
control switch to the OFF position.
9.  After  the  wiring  is  complete,  replace  the 
cover plate.
Note: The gas valve-mounted ON/OFF switch  
is shown in Figures 48 and 49. It is integral 
with  the  gas  valve  and  should  be  set  to  the 
ON position. 
BLOWER CONTROL CIRCUIT WIRING
120V, 60HZ, 1PH  
Factory Wired
Ground
Field Wired
Junction Box 
Tab Intact
Tab 
Broken
Plug blower
into this 
receptacle
ne
er
G - 
dn
uor
G
* Wall-mounted
ON/ OFF Blower 
Switch or Variable 
Speed Control Switch. 
Blower
eti
h
W - 
lar
tu
eN 12
VA
- B
la
ck
Green
Ground
Screw
W
hi
te
Gr
ee
n
Neutral 
Side of
Receptacle
Hot
Side of
Receptacle
Red
Black
Figure 50: Junction Box Wiring
A  sediment  trap  is  recommended  in  the  gas 
piping  within  the  home  to  prevent  moisture 
and debris in the line from damaging the valve.
These appliances are equipped with a gas flex 
line for use (where permitted) in connecting the 
unit to the gas line.  A gas flex line is provided 
to aid in attaching the direct vent appliance to 
the gas supply.  The gas flex line can only be 
used where local codes permit. Refer to Figure 
51  for flex line description. The flex line is rated 
for  both  natural  and  propane  gas.  A  manual 
shut off valve is also provided with the flex line.
The gas control valve is located in the lower 
control compartment. 
To  access  the  valve  open  the  lower  control 
compartment door (see Figure 52 ) by pushing 
in the right top corner of the door. (The door 
is hinged at the bottom.) Remove the bottom 
compartment  door  by  sliding  the  hinge  pin, 
located at the door’s left side, to the right until 
it disengages from the left corner post hole. 
Pull the door diagonally to the left, away from 
the fireplace.
The  millivolt  control  valve  has  a  3/8"  
(10 mm) NPT thread inlet port. The electronic 
control valve has a 1/2" (13 mm) NPT thread 
inlet port and is fitted with a 1/2" x 3/8" (13 mm x  
10 mm) NPT fitting.
Secure  all  joints  tightly  using  appropriate 
tools and sealing compounds (ensure propane 
resistant  compounds  are  used  in  propane 
applications).
All  codes  require  a  shut-off  valve  mounted 
in  the  supply  line.    The  orientation  of  the 
shut-off valve should face the front.  Figure 
51  illustrates two methods for connecting the 
gas supply.  A sediment Trap is recommended 
to prevent moisture and debris in the gas line 
for damaging the valve.
       WARNING 
Electronic models of these appli-
ances are equipped with a three-
prong (grounding) plug utilized 
in  connecting  the  electronic 
components to the junction box 
in the lower compartment.  This 
grounding plug provides protec-
tion  against  shock  hazard  and 
should be plugged directly into 
the  properly  grounded  three-
prong receptacle.  dO NOT cut 
or remove the grounding prong 
from the plug.
FBK-250 Blower Kit
(See Figure 49 on page 25)-
An  electrical  outlet  box  is  provided  for  the 
installation of the FBK-250 forced air blower 
kit.  Electrical power must be provided to this 
box to operate these blowers. Install the blower 
kit  according  to  the  installation  instructions 
provided with the kit.
Note:  The  tab  connecting  the  receptacles  of 
the outlet box must be  broken in FBK-100 and 
FBK-200 blower kit applications.  See Figure 50.
Step 7. CONNECTING GAS LINE 
Make gas line connections. All codes require a 
shut-off valve mounted in the supply line.  Figure 
51  illustrates two methods for connecting the 
gas supply. The flex-line method is acceptable 
in the U.S., however, Canadian requirements 
vary  depending  on  locality.  Installation  must 
be in compliance with local codes.  
Step 6.
 
WIRING - OPTIONAL FORCEd AIR 
BLOWER KIT 
FBK-100 and FBK-200 Kits 
(See Figure 48 on page 25) 
An  electrical  outlet  box  is  provided  for  the 
installation of the FBK-100FBK-200 forced air 
blower kits.  Electrical power must be provided 
to this box to operate these blowers. Install the 
blower kits according to the installation instruc-
tions provided with the kits.
     
WARNING
Never use an open flame to 
check for leaks.
TEST  ALL  CONNECTIONS  FOR  GAS  LEAKS 
(FACTORY ANd FIELd):