MAINTENANCE
WARNING
The use of substitute glass will 
void all product warranties.
Do not operate the appliance 
with the glass  panel(s) removed, 
cracked or broken. Replacement of 
the glass panel(s) should be done 
by an authorized service person.
GLASS 
REPLACEMENT
Your P42 fireplace is supplied with high 
temperature, 5 mm Neoceram ceramic glass 
that will withstand the highest heat that your 
unit will produce. In the event that you break the 
glass, purchase your replacement glass from an 
authorized Regency
®
 dealer only, and follow the 
step-by-step instructions for glass, glass gasket 
and door gasket replacement.
DOOR GLASS
Your Regency
®
 fi replace is supplied with high 
temperature, 5 mm Neoceram ceramic glass that 
will withstand the highest heat that your unit will 
produce.   If your glass requires cleaning, we 
recommend using an approved glass cleaner 
available at all authorized dealers. Do not use 
abrasive materials. Do not clean the glass 
when hot.
In the event that you break your glass by impact, 
purchase your replacement from an authorized 
Regency
®
 dealer only, and follow our step-by-
step instructions for replacement.
GOLD-PLATED 
LOUVERS
The 24 carat gold-plated fi nish on the louvers 
and trim requires little maintenance, and need 
only be cleaned with a damp cloth. 
DO NOT use abrasive materials or chemical 
cleaners, as they may harm the fi nish and void 
the warranty.
Clean any fi ngerprints off before turning 
the unit on.
LOG REPLACEMENT
The unit should never be used with broken logs. 
Turn off the gas valve and allow the unit to cool 
before opening door and carefully remove the 
logs. (The pilot light generates enough heat to 
burn someone.) If for any reason a log should 
need replacement, you must use the proper 
replacement log. The position of these logs 
must be as shown in the diagrams under Log 
Installation.
Note:  Improper positioning of logs may 
create carbon build-up and will 
severely alter the unit's performance 
w h i c h   i s   n o t   c o v e r e d   u n d e r 
warranty.
THERMOPILE / 
THERMOCOUPLE
1)  Remove the top louver and open the bottom 
louvers.
2)  Open and remove door.
3)  Remove front logs.
4) Remove 
burner.
5)  Loosen the thermocouple or thermopile with 
a 7/16" wrench.
6)  Disconnect thermocouple by loosening 
nut from the valve with a 9mm wrench. 
Disconnect thermopile by loosening 2 
screws marked TP on the valve.
7)  Peel the silicone from the hole in the base 
of the unit and drop the thermocouple or 
thermopile down from the bracket and pull 
it out of the unit.
8)  Reinstall the new ones in reverse order 
making sure to seal the hole in the fi rebox 
with silicone in order to maintain the seal 
integrity of the fi rebox.
Flush Glass Replacement
Remove the fl ush door front (as per instructions in 
the "Standard Flush Door" section). Remove the 
4 glass clips from each corner. Slide in the new 
r e p l a c e m e n t 
glass. Push the 
4 glass clips 
back onto the 
frame.  
The glass must 
have gasketing 
around it.
Caution: Wear gloves when removing 
damaged or broken glass.
Bay Glass Replacement
1)  Remove the door from the unit and place 
on a soft surface to prevent scratching.
2)  Remove the nuts holding the glass clips in 
place and remove.
3)   Replace the glass. The glass must have 
gasketing around it.
4)  Reverse the previous steps, replace the 
glass clips and fasten with the nuts but do not 
over tighten, as this can break the glass.
5)  Replace door on the fi replace and check 
the seal. 
WARNING: Do not operate the 
appliance with the glass panels 
removed, cracked or broken. 
Replacement of the glass  panels 
should be done by a licensed or 
qualifi ed service person.