Regency P40-NG1 User Manual

Page of 56
Regency
®
 P40-1 Direct Vent Gas Fireplace
26
INST
ALLA
TION
INSTALLATION
GAS PIPE PRESSURE 
TESTING
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut-off valve during any pressure 
testing of the gas supply piping system at 
test pressures equal to or less than 1/2 psig. 
(3.45  kPa).  Disconnect piping from valve at 
pressures over 1/2 psig.
The manifold pressure is controlled by a regulator 
built into the gas control, and should be checked 
at the pressure test point.
Note: To properly check gas pressure, both 
inlet and manifold pressures should 
be checked using the valve pressure 
ports on the valve.
1)  Make sure the valve is in the "OFF" 
position.
2)  Loosen the "IN" and/or "OUT" pressure 
tap(s), turning counterclockwise with a 
 1/8" 
wide 
fl at screwdriver.
3)  Attach manometer to "IN" and/or "OUT" 
pressure tap(s) using a 5/16" ID hose.
4)  Light the pilot and turn the valve to "ON" 
position.
5)  The pressure check should be carried out 
with the unit burning and the setting should 
be within the limits specifi ed on the safety 
label.
6) When fi nished reading manometer, turn 
off the gas valve, disconnect the hose and 
tighten the screw (clockwise) with a 1/8" fl at 
screwdriver. Note: Screw should be snug, 
but do not over tighten.
BACK-UP BATTERY 
INSTALLATION
(within Power Module)
1)  Unplug the power source.
2)  Remove the Power Module by lifting it up 
off of the velcro and pull out.
Power Module
3)  Remove the Power Module cover by 
removing the 2 screws, one on each side 
of the box.
4)  Install the 9V and AA battery.
SIT VALVE DESCRIPTION
1)  Gas on/off knob
2)  Electronically Operated Hi/Lo
3) Pilot 
Adjustment
4)  Thermocouple Connection - option
5)  Outlet Pressure Tap
6) Inlet Pressure Tap
7) Pilot Outlet
8)  Main Gas Outlet
9)  Alternative TC Connection Point
IN
OUT
1
3
5
6
4
2
NOTE:  The 9V battery operates the 
rear burner under power outage 
conditions.
 
 
The AA battery operates the DC 
Sparker for lighting the pilot.