Regency P40-NG1 User Manual

Page of 56
Regency
®
 P40-1 Direct Vent Gas Fireplace
36
INST
ALLA
TION
INSTALLATION
Diagram 1
Diagram 3
STANDARD 
FLUSH DOOR
NOTE:  Install Finishing Trim prior to installing 
the Flush Door and Louvers.
1)  The standard fl ush door comes with a black 
frame. To install the frame, simply hook the 
top door fl ange onto the top of the unit and 
swing the door towards the unit, diagram 
1.
Diagram 2
NOTE: Springs and chain must always 
be OVER not under the gas line. 
2)   Be careful that the glass gasket does not 
roll up; there must be a gap between the 
gasket and the door lip to ensure that the 
door sits securely on the unit. Diagram 2.
3)   Use the hook to pull the spring out until you 
can put the hook into the slot on the bottom 
door bracket. Repeat for 2nd spring.  See 
diagram 3.
 
4)  To remove the fl ush door, reverse the above 
steps.
FLUSH LOUVERS
NOTE:  Install Finishing Trim prior to installing 
the Flush Door and Louvers.
1)  Install the top louver by sliding the two bracket 
clips into the brackets located underneath 
the top of the fi rebox.
2)  Install the bottom louver by securing the 
louver onto the 2 hinges provided.
Note: Top and 
Bottom Louvers 
are different. 
3) Installing the Manual Control Box
a)  Ensure that the bottom louver is open.
b)  Pull out the Manual Control Box from the 
right side under the bottom of the fi rebox.
c)  Using the 2 screws on the louver, secure 
the control box onto the right side of the 
louver.
Manual Control Box
AERATION 
ADJUSTMENT
The rear burner aeration is factory set but may 
need adjusting due to either the local gas supply 
or altitude. 
The rear burner air shutter can be adjusted by 
moving the air shutter  knob located at the front 
left bottom louver opening. Open (pull) the air 
shutter wire for a blue fl ame or close (push) for 
a more yellow fl ame.
* The front burner aeration is factory set, do not       
adjust this setting.
Minimum Air Shutter Opening:
NG Front 
Burner* 1/8"
 Rear 
Burner 
1/8"
LP Front 
Burner* 
3/8"
 Rear 
Burner 
3/16"
CAUTION: Carbon will be produced if air shutter 
is closed too much. 
Note:   Any damage due to carboning 
resulting from improperly setting 
the aeration controls is NOT covered 
under warranty.
Aeration Adjustment should only be per-
formed by an authorized Regency
®
 Installer 
at the time of installation or service.
Adjustment Knob - Pull to open or
push to close aeration cap.
Rear Burner Adjustment Knob
Air Shutter 
Adjustment Wire