 L676E Direct Vent Gas Fireplace
13
INST
ALLA
TION
Vent restriction is required for certain venting 
installations, see the diagrams in the "Venting
Arrangements" section to determine if they are 
required for your installation.
The Vent Restrictor plate is located on the inside 
top of the fi rebox.
(factory set for NG units)
INSTALLATION
VENT RESTRICTOR 
POSITION
Screws for plugging the holes.
(all holes must be plugged with a screw).
Screw holes for fi xing the restrictor plate.
VENTING 
INTRODUCTION
The  L676E  uses  the  "balanced  fl ue"  technology 
Co Axial system. The inner liner vents products 
of combustion to the outside while the outer 
liner draws outside combustion air into the 
combustion chamber thereby eliminating the 
need to use heated room air for combustion and 
losing warm room air up the chimney.
Note: These flue pipes must not be 
connected to any other appliance.
The gas appliance and vent system must be 
vented directly to the outside of the building, 
and never be attached to a chimney serving a 
separate solid fuel or gas burning appliance. 
Each direct vent gas appliance must use it's own 
separate vent system. Common vent systems 
are prohibited.
Vent Restrictor Plate
To set the vent restriction as indicated in the 
venting arrangements diagrams, refer to the 
instructions below;
1)  Remove the glass door.
 
a.  Release the 2 door latches on the left      
     and right side at the top of the fi rebox.
 b.  
 Swing the door out from the top and release   
the hinges on the left and right side of the  
door by lifting them up.
Hinge
Door
Latch
Latch Location
2)   Remove the screws that hold the vent restric-
tor plate in place.
3)   Adjust the vent restrictor plate to the required 
vent restrictor position as per the diagrams 
shown.
4)      Once the vent restrictor plate is in the required 
position, secure with screws.
(factory set for LP units)