Regency P121-NG User Manual

Page of 40
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
22
CONVERSION  KIT  FROM  NG  TO  LPG  MODEL  #730-969
FOR  P121/P121LC/P121RC/P131  USING  SIT  820  NOVA  GAS  VALVE
THIS CONVERSION MUST BE DONE BY A AUTHORIZED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
6) Pull  off  the  pilot
cap to expose the
pilot orifice.
7) Unscrew the pilot  orifice with the allen key
and replace with the LPG pilot orifice in the
kit and replace pilot cap.
10) Reinstall new burner orifice LPG stamped
#50 and tighten.
11) Remove and discard the 3 pressure regu-
lator mounting screws (A), pressure regu-
lator tower (B) and diaphragm (C).
12) Insure that the rubber gasket (D) is properly
positioned and install the new HI/LO pres-
sure regulator assembly to the valve using
the  new  screws  (E)  supplied  with  the  kit.
Tighten  screws  securely.
13) Reverse steps 4) to 1).
9) Remove burner orifice with a 1/2" spanner
and discard. Use another spanner to hold
on to the elbow behind the orifice.
Burner  Orifice
Conversion Kit Contains:
Qty. Part #
Description
1 910-018
SIT Conversion Kit-50%
Turndown  LPG
1 910-037
LPG Injector (Pilot Orifice)
1 *
Burner Orifice #50
1 908-255
Decal "Converted to LPG"
1 908-529
5/32" Allen Key
1 918-032
Instruction Sheet
1) Remove the louvers and trim kit. Remove the
front  door.
2) Remove the logs, embers.
3) Remove  the  grate  by  lifting  straight  up.
Remove the side brick panels (if installed).
The brick panel is very  fragile - handle
with  care.
Diagram 1: Remove the left and right
screws  and  then  slide  the  burner  assembly
away from the orifice and lift out.
4) Remove the burner assembly by removing
the 4 Phillips head screws and then slide
the burner assembly away from the orifice
and lift out.
14) Attach clear label "This unit has been con-
verted to LPG" near or on the serial # decal.
Attach  white  label  "This  valve  has  been
converted from NG to LPG using SIT con-
version Kit  Code 0.907.202" onto the valve.
15) Replace yellow "NG" label with red "LPG"
label
16) Check for gas leaks.
17) Check inlet and outlet pressures.
18) Check operation of flame control.
19) Check  for  proper  flame  appearance  and
glow  on  logs.
INSTALLATION
5) Remove  pilot  inner
box by removing the
2  screws.
8) Re-install pilot inner box using 2 screws.