Regency L900-LP User Manual

Page of 56
Regency
®
 L900 Direct Vent Gas Fireplace
23
INST
ALLA
TION
INSTALLATION
Diagram 7
Diagram 5
7)  Ensure that  the pipe clearances to 
combustible materials are maintained 
(Diagram 5). Install the termination cap.
Note:  If installing termination on a vinyl 
siding covered wall, a vinyl siding 
standoff or furring strips must be used 
to ensure that the termination is not 
recessed into the siding.
 
The four wood screws provided should be re-
placed with appropriate fasteners for stucco, 
brick, concrete, or other types of sidings.
8)  Before connecting the horizontal run of vent 
pipe to the vent termination, slide the Wall 
Thimble  over the vent pipe. The wall thimble 
is required for all horizontal terminations.
9)  Slide the appliance and vent assembly 
towards the wall carefully inserting the vent 
pipe into the vent cap assembly. It is important 
that the vent pipe extends into the vent cap 
suffi cient distance so as to result in a minimum 
pipe overlap of 1-1/4 inches (32mm). Secure 
the connection between the vent pipe and 
the vent cap.
10) Install wall thimble in the center of the 11"  
(279mm) square and attach with wood screws 
(Diagram 7).
UNIT INSTALLATION 
WITH HORIZONTAL 
TERMINATION
(Rigid Vent Systems)
A top clearance of 3"(76mm) and side & bottom 
clearance of 2"(51mm) must be maintained; 
except when passing through a wall, ceil-
ing, or at the termination where the use of a 
fi restop or wall thimble reduces the required 
clearance to 1-1/2" (38mm). We recommend 
framing a 11"(279mm) x 11"(279mm) (inside 
dimensions) hole to give structural rigidity 
for mounting the termination.
Install the vent system according to the 
manufacturer's instructions included with the 
components.
1)  Set the unit in its desired location. Check to 
determine if wall studs or roof rafters are in 
the way when the venting system is attached. 
If this is the case, you may want to adjust 
the location of the unit. Rough in the gas 
preferably on the right side of the unit and 
the electrical (junction block is on the left 
side) on the left.
2)  Direct Vent pipe and fi ttings are designed with 
special twist-lock connections to connect the 
venting system to the appliance fl ue outlet. 
A twist-lock appliance adaptor is required.
3)  In conjunction with the Simpson Dura-Vent 
Direct Vent GS system. Install the adaptor 
after the unit is set in its desired location. 
Put a bead of high temperature silicone 
inside the outer section of the adapter and 
a bead of Mill Pack on the inner collar. Slip 
the adapter over the existing inner and outer 
fl ue collar. Fasten to the outer collar only with 
the 3 supplied screws (drilling pilot holes will 
make this easier).
4) Level 
the 
fi replace and fasten it to the framing 
using nails or screws through the top and 
side nailing strips.
5)  Assemble the desired combination of pipe 
and elbows to the appliance adaptor and 
twist-lock for a solid connection.
Note:   For best results and optimum 
performance with each approved 
v e n t i n g   s y s t e m ,   i t   i s   h i g h l y 
recommended to apply “Mill-Pac” 
sealant (supplied) to every inner pipe 
connection. Failure to do so may result 
in drafting or performance issues not 
covered under warranty. Silicone (red 
RTV) is optional.
Diagram 1
6)  Mark the wall for a 11" x 11" (279mm x 
279mm) square hole. The center of the 
square hole should line up with the center-
line of the horizontal pipe. Cut and frame the 
11 inch  (279mm) square hole in the exterior 
wall where the vent will be terminated. See 
diagram 2 for center line requirements.
 
If the wall being penetrated is constructed of 
non-combustible material, i.e. masonry block 
or concrete, an 8" (203mm) diameter  hole 
is acceptable.
Diagram 2
Note:
 a)
  The horizontal run of vent must be level, 
or have a 1/4 inch rise for every 1 foot 
of run towards the termination. Never 
allow the vent to run downward. This 
could cause high temperatures and may 
present the possibility of a fi re. 
 
b)  The location of the horizontal vent 
termination on an exterior wall must meet 
all local and national building codes, and 
must not be blocked or obstructed.  See 
"Exterior Vent Termination Locations" 
section for more details.
Horizontal runs of vent must be supported 
every 3 feet (0.9meter). Wall straps are 
available for this purpose.
NOTE:  A Vent Guard is required when 
the AstroCap is installed above grade 
at 7 feet or lower.