MAINTENANCE
MAINTENANCE
3)   Loosen the 2 screws that hold the left side  
heat shield in place.
4)   Lift up and pull out the heat shield slightly 
to clear the screwheads and then hang it 
on the top bracket (located directly above 
the heat shield).
8)  Remove the battery cover from the DC 
Sparker Box.
9)   Disconnect all the wires and connectors 
from the DC sparker.
10) Remove the 2 screws that hold the DC 
sparker.
1)   Remove the exterior brick panels.
2)   Remove the glass door.
Battery Cover
DC SPARKER REPLACEMENT
 
a.  Release the 2 door latches on the left      
     and right side at the top of the fi rebox.
 b.  
 Swing the door out from the top and release   
the hinges on the left and right side of the  
door by lifting them up.
Hinge
Door
Latch
Latch Location
Heat 
Shield
Bracket
Heat 
Shield
11) Replace the DC sparker.
12) Reverse steps to re-install.
6)  Loosen the 2 screws that hold the right  
side heat shield.
7) Lift up and pull out the heat shield slightly to 
clear the head screws and then hang it on 
the top bracket (located directly above the 
heat shield). 
Bracket
Heat 
Shield
Heat 
Shield
5)  Unplug the power source.