Regency L900-LP User Manual

Page of 56
Regency
®
 L900 Direct Vent Gas Fireplace
47
MAINTENANCE
1)   Remove the exterior brick panels.
2)   Remove the glass door.
VALVE TRAY REPLACEMENT
 
a.  Release the 2 door latches on the left      
     and right side at the top of the fi rebox.
 b.  
 Swing the door out from the top and release   
the hinges on the left and right side of the  
door by lifting them up.
Hinge
Door
Latch
Latch Location
  c.   Place the door on a soft surface to prevent 
scratching.
Heat 
Shield
3)  Loosen the 2 screws that hold the left side  
heat shield in place.
4)   Lift up and pull out the heat shield slightly 
to clear the screwheads and then hang it 
on the top bracket (located directly above 
the heat shield).
Bracket
Heat 
Shield
5)  Unplug the power source.
6)   Remove the log set.
7)   Remove the interior brick panels.
8)   Remove the grate by undoing the 2 screws 
on the right and left side.
9) Remove the front burner by removing the  
    screw.
10)  Remove the back burner by removing the  
       screw.
11)  Remove the rear log stand by removing  
       the 4 screws.
MAINTENANCE
Grate
Front Burner
Front Burner Removed
Back Burner
Rear Log Stand