Regency P48-NG2 User Manual

Page of 7
P48  Zero Clearance Direct Vent Gas Fireplace
Model
P48-NG2
P48-LP2
Fuel Type
Natural Gas
Propane
Minimum Supply Pressure
5” W.C. (1.25 kPa)
12” W.C. (3.00 kPa)
Manifold Pressure - High
3.8” W.C. (0.95 kPa)
11” W.C. (2.74 kPa)
Manifold Pressure - Low
1.1” W.C. (0.27 kPa)
3.3” W.C. (0.82 kPa)
Orifi ce Size
#27 DMS - 0-4500ft
#47 DMS
Minimum Input 
29,000 BTU/h (8.49 kW)
26,000 BTU/h (3.07 kW)
Maximum Input
51,000 BTU/h (14.94 kW)
48,000 BTU/h (6.30 kW)
Vent Sizing
5” Inner / 8” Outer
5” Inner / 8” Outer
A
B
A
D
C
F
E
G
H
I
K
J
L
O P
N
M
11" (279mm)
dia. Hole through
wall Vent.
Opening for gas
connection
Top Header
Drywall
(or other
facing)
P48 Gas Fireplace
Unit Dimensions
Description
P33
A
Front Face Width
48” (1219mm)
B
Rear Firebox Width
34-1/2” (876mm)
C
Front Face Height
41” (1041mm)
D
Height w/ Standoff
47” (1193mm)
E
Unit Depth
23-1/4” (324mm)
F
Firebox Height
40” (1016mm)
Framing Dimensions
Description
P33
G
Framing Width
48-1/2” (1232mm)
H
***
Framing Height
***
47-1/2” (1207mm)
***
I
Framing Depth
29-3/4” (756mm) Vertical Rise
26-1/4” (667mm) No Vertical Rise 
J
Corner Wall Length
57-5/8
 
” (1464mm)
K
Corner Facing Wall Width
81-1/2” (2070mm)
L
Framed Chase Ceiling
N/A - Vertical Rise
50” (1270mm) No Vertical Rise 
M
Vent Centerline Height
43” (1092mm) 
N
Gas Connection Height
2” (51mm)
O
Gas Connection Inset
3-3/4” (95mm) 
P
Gas Connection Width
5” (127mm) 
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Dura-Vent® Direct Vent GS
***
Important:  Framing height requires consideration of the hearth 
depth.   Dimension H = H + the thickness of installed hearth.
Please refer to Page 11 (Exterior Vent Terminations) 
for additional guidelines on vent locations.
61
June 2007 Regency Product Specifi cations Book
Gas Fireplaces
Gas Fir
eplaces