Regency P48-NG2 User Manual

Page of 7
8" dia.
Flue pipe
5” dia.
Flue pipe
Spring Spacer
AstroCap XL
(Part# 946-623/P)
Wall Thimble
Vinyl Siding
Standoff
Alternate Horizontal 
Termination Caps
Snorkel Terminations
Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building, 14-
inch and 36-inch tall Snorkel Terminations are available. Follow the same 
installation procedures as used for standard Horizontal Termination. 
NEVER install the snorkel upside down.
Min. 12"*
(305mm)
Dura-Vent
Snorkel
Below Grade Snorkel Installation (Dura-Vent Only)
If the Snorkel Termination must be installed below grade, i.e. basement 
application, proper drainage must be provided to prevent water from 
entering the Snorkel Termination. Refer to Rigid Pipe Installation 
instructions for details. Do not attempt to enclose the Snorkel within the 
wall, or any other type of enclosure.
Min.
12"*
(305mm)
Adequate
drainage
Window
Well
Gravel
Dura-Vent
Snorkel
P48 Gas Fireplace
Regency Direct  Vent System (Flex)
Horizontal Terminations Only
These venting systems, in combination with the P48 Direct Vent Gas 
Fireplace, have been tested and listed as a direct vent heater system 
by Warnock Hersey. The location of the termination cap must conform 
to the requirements in the Vent Terminal Locations diagram.
FPI Direct Vent (Flex) System Termination Kits include all the parts 
needed to install the P48 using a fl exible vent.
FPI Kit # 
Length 
Contains:
#946-618
6 Feet
1) 
6-5/8” fl exible liner (Kit length)
2) 
4” fl exible liner (Kit length)
3) spring 
spacers 
(3)
4) thimble 
(2)
5) 
AstroCap termination cap (1)
6) screws 
(12)
7) 
tube of Mill Pac (1)
8) plated 
screws 
(8)
9) 
S.S. screws #8 x 1-1/2” drill point, (4)
10)  vinyl siding standoff
#946-616
10 Feet
Notes: 
1) 
Liner sections should be continuous without any joints or seams.
2) 
Only Flex pipe purchased from Regency may be used for Flex 
installations.
3) 
Horizontal sections must be supported every 3 feet.
If required by the external termination location the listed 
alternate termination caps may be used.  (Refer to Page 11)
Alternate Snorkel
Termination Cap
Part #1282 (14”)
Part #1281 (36”)
63
June 2007 Regency Product Specifi cations Book
Gas Fireplaces
Gas Fir
eplaces