Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
17
INSTALLATION
FLUEING ARRANGEMENTS  -  VERTICAL  TERMINATIONS
SIMPSON DURA-VENT DIRECT VENT GS SYSTEM
 
(LPG & NG)
•
Flue  must  be  supported  at  offsets
•
Maintain  clearances  to  combustibles  as  listed  on  page  9.
•
Firestops  are  required  at  each  floor  level  and  whenever  passing  through  a  wall.
•
Must  use  optional  flue  adapter  when  using  Simpson  Dura-Vent  pipe  (Part#  510-994).
The P121/P121LC/P121RC/P131 is approved for a maximum 35 ft. (10.7m) straight vertical, with Simpson Dura-Vent Direct Vent GS flue systems
for LPG and NG, as per diagram 7 below.
Diagram  7
Diagram  8
Straight Up Vertical Flueing
Vertical Flueing with One (1) 90
o
 Elbow
Option
V
H
     A)
1'  (305mm)  Minimum
2' (610mm) Maximum
     B)
2'  (610mm)  Minimum
4' (1.22m) Maximum
     C)
3'  (914mm)  Minimum
6' (1.86m) Maximum
     D)
4'  (1.22m)  Minimum
8' (2.4m) Maximum
With the above options, maximum total pipe length if 37 feet with
minimum of 4 feet total vertical and maximum 8 feet total horizontal.
Please note minimum 1 foot between 90
o
 elbows is required.