P40 Direct Vent Gas Fireplace
18
INST
ALLA
TION
H
H1
V
Horizontal Venting with Two (2) 90
o
Elbows
Horizontal Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
Option V
H + H1
A)
2' Min. 2' Max.
B)
3' Min. 5' Max.
C)
4' Min. 6' Max.
D)
5' Min. 7' Max.
E)
6' Min. 8' Max.
W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Option V
H V + V1 H + H1
A)
0' Min. 1' Max. 1' Min. 1' Max.
B)
1' Min. 2' Max. 3' Min. 3' Max.
C)
2' Min. 2' Max. 5' Min. 4' Max.
D)
3' Min. 2' Max. 7' Min. 5' Max.
E)
4' Min. 3 Max. 9' Min. 6' Max.
F)
5' Min. 4' Max. 10' Min. 7' Max.
G)
6' Min. 5' Max. 11' Min. 8' Max.
H)
7' Min. 6' Max. 12' Min. 9' Max.
With these options,
max. total pipe length
is 30 feet with min. of
12 feet total vertical
and max. 9 feet total
horizontal.
max. total pipe length
is 30 feet with min. of
12 feet total vertical
and max. 9 feet total
horizontal.
Please note min. 1
foot between 90
foot between 90
o
elbows is required.
VENT RESTRICTOR SETTING:
When total vertical exceeds total horizontal by 2x the vent
restrictor setting is set to 1.
When total vertical exceeds total horizontal by 2x the vent
restrictor setting is set to 1.
Please note minimum 1 foot between 90
o
elbows is
required.
INSTALLATION
VENT RESTRICTOR SETTING:
When total vertical exceeds total horizontal by 3x the vent restrictor
setting is set to 1.
When total vertical exceeds total horizontal by 3x the vent restrictor
setting is set to 1.