Regency P40 User Manual
Regency
®
P40 Direct Vent Gas Fireplace
19
INST
ALLA
TION
V
H1
H
V1
V1
V
H
Vertical Venting with Two (2) 90
o
Elbows
Vertical Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
Option V
H
V + V1
A)
0' Min. 2' Max. 1' Min.
B)
1' Min. 4' Max. 2' Min.
C)
2' Min. 5' Max. 3' Min.
D)
3' Min. 6' Max. 4' Min.
E)
4' Min. 7' Max. 5' Min.
F)
5' Min. 8' Max. 6' Min.
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
between 90
o
elbows is
required.
For additional vertical venting with 2
x 90
x 90
o
elbows, refer to next page.
Option V
H + H1 V + V1
A)
0' Min. 2' Max. 3' Min.
B)
1' Min. 2' Max. 3' Min.
C)
2' Min. 3' Max. 4' Min.
D)
3' Min. 4' Max. 6' Min.
E)
4' Min. 5' Max. 7' Min.
F)
5' Min. 6' Max. 8' Min.
G)
6' Min. 7' Max. 9' Min.
H)
7' Min. 8' Max. 10' Min.
With these options, max.
total pipe length is 30 feet
with min. of 10 feet total
vertical and max. 8 feet
total horizontal.
total pipe length is 30 feet
with min. of 10 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90
between 90
o
elbows is
required.
INSTALLATION
VENT RESTRICTOR SETTING:
When total vertical exceeds total horizontal by 2x the vent restrictor
setting is set to 1.
When total vertical exceeds total horizontal by 2x the vent restrictor
setting is set to 1.
VENT RESTRICTOR SETTING:
When total vertical exceeds total horizontal by 3x the vent
restrictor setting is set to 1.
When total vertical exceeds total horizontal by 3x the vent
restrictor setting is set to 1.