Quadra-Fire 7051-158B User Manual

Page of 58
Page  36
7051-158B
December 6, 2011
EDGE 60 Pellet Fireplace 
E.  Thermostat Wall Control Installation
Consideration should be given to the mounting material 
when installing the wall control.
If mounting the wall control to a sheet rock surface you 
should use the provided anchors for mounting. 
If mounting the wall control to a wood surface or an electri-
cal outlet box then the fasteners provided will suffi ce and 
the anchors need not be used.
1.  Remove the front cover of the wall control by prying the 
cover off with a small screwdriver or your fi ngernail. Place 
the front side to the packaging to protect it from damage 
while installing the sub base. 
2.  Route the wires into the wall control leaving only the 
amount necessary to make the connection to the terminal 
block in the upper left hand corner remaining. The wires are 
routed to the terminal block according to the letters printed 
in the thermostat sub base.
Red at the top
Green in the middle
White at the bottom 
3.  Push as much extra wire as possible back into the wall 
and seal the hole in the wall with putty or insulation. 
4.  When re-installing the cover make sure that the wire 
routing does not interfere with any of the components. 
Make adjustments as needed and snap cover back into 
place making sure that all locking tabs snap into place.
Red Wire
Top
Bottom
White Wire
Green Wire
Figure 35.1- Back Side of Wall Control with 
Cover Off
F.  Installing Flue Collar, Vertical or Horizontal 
The fi replace ships from the factory without the fl ue collar 
and gasket attached.  They are located in the component 
pack inside the fi rebox.  Follow the steps below for a vertical 
or horizontal installation.
Vertical Installation
1.  Remove the fl ue collar and gasket from the component 
pack.  Push out the 6 slugs in the gasket.
2.  Remove both the top and rear cover plates.  Save screws 
and plates for later re-attachment.
3.  Place the orange fl ue gasket over the locating pins on 
the exhaust fl ue transition on the back of the fi replace.  
Figure 35.2.
4.  Insert the fl ue pipe through the top cover plate.  
5. Before inserting the fl ue collar into the pipe, liberally 
silicone the end of the fl ue collar with Hi-Temp silicone 
about 1-1/2 inches (38mm) wide. Figure 36.1 on page 
36.
NOTE:  You will need to install one section of 3 inch (76mm) 
diameter vent pipe to clear the outer can cover plate before 
installing a 3 to 4 inch (76-102mm) pellet pipe adapter for 
the balance of the venting.
6.  Lay the fi rst section of pipe on its side for screw attach-
ment. The 2 screws need to be directly above the locat-
ing pins, 180 degrees apart.  Figure 36.2 on page 36.
7. Drill holes through the pipe walls directly into the fl ue 
collar.  Attach screws through pipe into fl ue collar.
8.  Carefully feed the fl ue collar and pipe through the outer 
can top fl ue opening and guide the fl ue collar base plate 
over the 2 locating pins.  Secure with 4 screws provided 
in component pack.
9.  Re-attach the top cover plate to the top of the fi replace 
and the rear cover to the back of the outer can.  Figure 
36.4 on page 36.
NOTICE:  The thermostat wall control should be mounted 
on an inside wall and not in direct line with the appliance 
convection air.
NOTICE:  If the thermostat wall control is located too close 
to the appliance, you may need to set the temperature setting 
slightly higher to maintain the desired temperature in your 
home.
Locating Pins
4 screws in outer corner holes
Figure 35.2- Install Orange Flue Gasket