 Regency E21 Gas Fireplace Insert
HIGH ELEVATION
This  unit  is  approved  in  Canada  for  altitude 
0  to  4500  ft.  (CAN/CGA  2.17-M91)  with  the 
orifi ce supplied.
System Data
For altitude:  Natural Gas  0-2000 ft.   
 
 
Propane: 
0-4500 ft.
Burner Inlet Orifi ce Sizes:
                           Natural Gas   Propane
   Burner 
#43           #54                     
Max. Input Rating 
  - Natural Gas 
23,500 Btu/h
- Propane 
22,500 Btu/h
Min. Input Rating 
- Natural Gas
--
+/-5%  11,750 Btu/h
  -Propane      +/-5%  11,250 Btu/h 
Supply Pressure
  Natural Gas 
min.  5.0" w.c.
  Propane 
min.  12.0" w.c. 
Manifold Pressure  (High)
  Natural Gas 
3.8"   +/- 0.2" w.c.
  Propane 
11"   +/- 0.2" w.c.
Circulation Fan: 120 VAC, 60 Hz
Variable Speed:  127 CFM, thermally  
activated
NATURAL GAS  E21-NG1
For altitude:        2000 ft - 4500 ft.
Burner Inlet Orifi ce Size: 
44 DMS
Max. Input Rating 
22,000 Btu/h
Min. Input Rating 
+/-5% 11,000 Btu/h
INSTALLATION
GAS CONNECTION
Only persons licensed to work with gas piping 
may make the necessary gas connections to 
this appliance.  
The gas connection is a 3/8" NPT accessible on 
the left side of the unit.  The gas line connection 
may be made of rigid pipe, copper pipe or an 
approved fl ex connector. (If you are using rigid 
pipe,  ensure  that  the  valve  can  be  removed 
for servicing.) Since some municipalities have 
additional local codes it is always best to consult 
with your local authorities and the CAN/CGA 
B149 installation code.
For USA installations follow local codes and/or 
the  current  National  Fuel  Gas  Code,  ANSI 
Z223.1.
When using copper or fl ex connectors use only 
approved fi ttings. Always provide a union so that 
gas lines can be easily disconnected for burner 
or fan servicing. Flare nuts for copper lines and 
fl ex connectors are usually considered to meet 
this requirement.
Important:  Always check for gas leaks 
with a soap and water solution or gas 
leak detector. Do not use open fl ame 
for leak testing.
For minimum and maximum supply pressure 
see the System Data table.
1)  If  the  appliance  is  to  be  installed  into  an 
existing chimney system, thoroughly clean 
the masonry fi replace that has been chosen 
for the Regency Gas Fireplace.
2)  The appliance is provided with an opening on 
the left hand side of the control compartment 
for the gas line.
Note: During any pressure testing of the gas 
supply piping system that exceeds test pressures 
of  1/2  psig,  this  appliance  and  its  individual 
shut-off valve must be disconnected from the 
piping system.  If test pressures equal to or less 
than 1/2 psig are used then this appliance must 
be isolated from the piping system by closing 
its individual manual shut-off valve during the 
testing.
CAUTION:    If  the  glass  is  removed  for 
servicing,  it  must  be  replaced  prior  to 
operating  the  appliance.    The  glass  must 
be  fixed  in  the  closed  position  when 
operating.