Vermont Casting 2478 User Manual
14
Dutchwest Non-Catalytic Convection Heater
30002278
Distance from Center of Flue Collar to Wall in Top-Exit Installations
Dutchwest Convection Heater Model 2478
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col-
lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the
wall protector.
lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the
wall protector.
ST427
dutchwest
flue centerline
6/30/00 djt
A
B
C
E
D
F
C
F
Chimney Connector
Side
Rear
Corner
Side
Rear
Corner
Listed, Approved
(A) 30”
(B) 13”
(C) 18¹⁄₂”
(D) 21”
(E) 12¹⁄₂”
(F) 18”
Double-wall, with
(762 mm)
(330 mm)
(470 mm)
(533 mm)
(318 mm)
(457 mm)
flue collar shield
Single wall, with
Single wall, with
(A) 27”
(B) 13”
(C) 18¹⁄₂”
(D) 20”
(E) 9”
(F) 15”
Connector heat shields
(686 mm)
(330 mm)
(470 mm)
(508 mm)
(229 mm)
(381 mm)
and flue collar shield
Single wall with no
Single wall with no
(A) 33”
(B) 23”
(C) 26¹⁄₂”
(D) 20”
(E) 17”
(F) 21¹⁄₂”
heat shields
(838 mm)
(584 mm)
(673 mm)
(508 mm)
(432 mm)
(546 mm)
UNPROTECTED SURFACES
PROTECTED SURFACES
Corner
Corner
Parallel Installations
Installations Parallel Installations
Installations
ST427