Vermont Casting 2478 Manuale Utente

Pagina di 32
14
Dutchwest Non-Catalytic Convection Heater
30002278
Distance from Center of Flue Collar to Wall in Top-Exit Installations
Dutchwest Convection Heater Model 2478
NOTE: These are not clearance distances.  These measurements indicate where the centerline of the flue col-
lar will be for various installations.  Measurements are from the centerline of the flue collar to the wall, not the 
wall protector. 
ST427
dutchwest
flue centerline
6/30/00   djt
A
B
C
E
D
F
C
F
 
 Chimney Connector 
Side 
Rear 
 Corner 
Side 
Rear 
Corner 
  Listed, Approved 
(A)  30” 
(B) 13” 
(C) 18¹⁄₂” 
(D)  21” 
(E) 12¹⁄₂” 
(F)  18” 
 
  Double-wall, with 
(762 mm) 
(330 mm) 
(470 mm) 
(533 mm) 
(318 mm) 
(457 mm)   
  flue collar shield
  Single wall, with 
(A)  27” 
(B)  13” 
(C)  18¹⁄₂” 
(D)  20” 
(E)  9” 
(F)  15” 
 
  Connector heat shields 
(686 mm) 
(330 mm) 
(470 mm) 
(508 mm) 
(229 mm) 
(381 mm)   
  and flue collar shield
  Single wall with no 
(A)  33”  
(B)  23” 
(C)  26¹⁄₂” 
(D)  20” 
(E)  17” 
(F)  21¹⁄₂”   
  heat shields 
(838 mm) 
(584 mm) 
(673 mm) 
(508 mm) 
(432 mm) 
(546 mm)
          
UNPROTECTED SURFACES 
PROTECTED SURFACES
 
 
Corner 
 
Corner
 
Parallel Installations 
Installations  Parallel Installations 
Installations
ST427