Troubleshooting
309524L
17
Troubleshooting
Problem
Cause
Solution
Heater will not heat.
No current.
Check circuit and fuses.
Check continuity of primary thermo-
stat (24), backup thermostat (10), 
and thermal limit sensor (15).
Check continuity of thermostat (10) 
and heater block (3) terminals - Page 
18.
Burned out heater block (3).
Replace block - Page 20.
Blown heat limiter (15).
Check continuity of primary thermo-
stat (24) and backup thermostat (10). 
Replace thermostats if necessary 
when replacing thermal limit sensor 
(15) - Pages 18-20.
Temperature too low.
Fluid requires more warm-up time.
Increase warm-up time.
Wrong temperature setting.
Adjust setting - Page 15.
Flow rate too high.
Reduce flow rate or use 2 heaters.
Clogged fluid passages.
Flush regularly - Page 16.
Temperature too high.
Wrong temperature setting.
Adjust setting - Page 15.
Failed primary thermostat (24).
Replace - Page 18.
High fluctuating temperatures, about 
220-250°F (104-120°C) at 0.1 GPM.
Primary thermostat (24) contacts 
sticking.
Replace thermostats (24, 10) - Page 
18. Note that backup thermostat (10) 
keeps heater functioning for only a 
short time.
Too much pressure drop or fluid will 
not flow.
Flow rate too high.
Reduce flow rate or use 2 heaters.
Clogged fluid passages.
Flush regularly - Page 16.
Heater fittings leak.
Loose or damaged fittings.
Tighten fittings or replace heater 
block - Page 20.
F
IG
. 14: Electrical Schematic
F
R
300°F
230°F
255°F
(110°C)
OFF
a
1
e
2
(149°C)
(124°C)
e
1
SL
Mp
R
6-55 ohm
05556-524