Graco 309524L Manual De Usuario

Descargar
Página de 30
Troubleshooting
309524L
17
Troubleshooting
Problem
Cause
Solution
Heater will not heat.
No current.
Check circuit and fuses.
Check continuity of primary thermo-
stat (24), backup thermostat (10), 
and thermal limit sensor (15).
Check continuity of thermostat (10) 
and heater block (3) terminals - Page 
18.
Burned out heater block (3).
Replace block - Page 20.
Blown heat limiter (15).
Check continuity of primary thermo-
stat (24) and backup thermostat (10). 
Replace thermostats if necessary 
when replacing thermal limit sensor 
(15) - Pages 18-20.
Temperature too low.
Fluid requires more warm-up time.
Increase warm-up time.
Wrong temperature setting.
Adjust setting - Page 15.
Flow rate too high.
Reduce flow rate or use 2 heaters.
Clogged fluid passages.
Flush regularly - Page 16.
Temperature too high.
Wrong temperature setting.
Adjust setting - Page 15.
Failed primary thermostat (24).
Replace - Page 18.
High fluctuating temperatures, about 
220-250°F (104-120°C) at 0.1 GPM.
Primary thermostat (24) contacts 
sticking.
Replace thermostats (24, 10) - Page 
18. Note that backup thermostat (10) 
keeps heater functioning for only a 
short time.
Too much pressure drop or fluid will 
not flow.
Flow rate too high.
Reduce flow rate or use 2 heaters.
Clogged fluid passages.
Flush regularly - Page 16.
Heater fittings leak.
Loose or damaged fittings.
Tighten fittings or replace heater 
block - Page 20.
F
IG
. 14: Electrical Schematic
F
R
300°F
230°F
255°F
(110°C)
OFF
a
1
e
2
(149°C)
(124°C)
e
1
SL
Mp
R
6-55 ohm
05556-524