16934-3-0806
Flames from the pilot (rear right back side of the pan burner) as 
well as the main flame should be visually checked as the log set 
is installed.
In normal operation at full rate after 10 to 15 minutes, the flame 
appearance should be sets of yellow flames.
NOTE: All flames will be random by design, flame height will 
go up and down.
Glowing embers (rock wool) can cover the pan burner in between 
the front and middle logs, but very little is necessary to cover this 
area. Excess ember material causes the yellow flame to become 
orange and stringy. Apply just enough to obtain slow glow and a 
gold yellow flame.
Avoid any drafts that alter burner flame patterns. Do not allow 
fans to blow directly into fireplace. Do not place a blower inside 
the burner area of the firebox. Ceiling fans may create drafts that 
alter flame patterns. Sooting and improper burning will result.
OPERATION INSTRUCTIONS/FLAME APPEARANCE
THERMOSTAT OPERATION
Millivolt Control has four (4) positions
 
Off  –  All gas to set is completely off at the valve.
 
Pilot  –  Valve  position  to  light/maintain  the  standing 
pilot.
 
Low  –  Minimum  gas  rate  -  pleasing  yellow  flames  - 
glowing embers.
 
High  –  Maximum  gas  rate  -  pleasing  yellow  flames  - 
glowing embers.
Generator 
  Ignition  –  Piezo Ignitor allows lighting of the pilot without 
matches.
 
Pilot  –  All gas log heaters are designed with safety pilot 
systems  that  will  shut  down  when  the  level  of 
oxygen available in the room is low. The pilot will 
only relight when adequate fresh air is available.
  Thermo  –  All millivolt logs are fitted with a thermo generator 
to provide millivolt power to activate switches, 
remote controls or thermostats.
During  manufacturing,  fabricating  and  shipping,  various 
components of this appliance are treated with certain oils, films or 
bonding agents. These chemicals are not harmful, but may produce 
annoying smoke and smells as they are burned off during the initial 
operation of the appliance, possibly causing headaches or eye or 
lung irritation. This is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner 
at the highest setting. Provide maximum ventilation by opening 
windows or doors to allow odors to dissipate. Any odors remaining 
after this initial break-in will be slight and will disappear with 
continued use.