Empire Comfort Systems CHBR-16-3 User Manual

Page of 20
Page 14
16934-3-0806
Figure 7 shows a correct pilot flame pattern. The correct flame 
will  be  blue  and  will  extend  beyond  the  thermocouple.  The 
flame will surround the thermocouple just below the tip. A slight 
yellow flame may occur where the pilot flame and main burner 
flame meet. Figure 8 shows an incorrect pilot flame pattern. The 
incorrect pilot flame is not touching the thermocouple. This will 
cause the thermocouple to cool. When the thermocouple cools, 
the heater will shut down.
Correct appearance of pilot flame.
Figure 7
 Incorrect appearance of pilot flame.
Figure 8
If pilot flame pattern is incorrect, as shown in Figure 8
•  See Troubleshooting, page 17.
Cleaning and Maintenance/Pilot
Oxygen Depletion Sensor Pilot (Figure 9)
When the pilot has a large yellow tip flame, clean the Oxygen 
Depletion Sensor as follows:
1.  Clean the ODS pilot by loosening nut B from the pilot tubing. 
When this procedure is required, grasp nut A with an open end 
wrench.
2.  Blow air pressure through the holes indicated by the arrows. 
This will blow out foreign materials such as dust, lint and 
spider webs. Tighten nut B also by grasping nut A. 
Figure 9
Warning: 
Never  use  needles,  wires,  or  similar  cylindrical  objects  to 
clean  the  pilot  to  avoid  damaging  the  calibrated  ruby  that 
controls the gas flow.
PILOT FLAME CHARACTERISTICS