WIRING
Label all wires prior to disconnection when servicing controls. 
Wiring errors can cause improper and dangerous operation. 
Verify proper operation after servicing.
Control Panel Installation
1.  Disconnect black and green wire from TH/TP and TH terminal 
on valve.
2.  Insert REMOTE/OFF/ON switch with attached wires through 
rectangular opening on cover plate.
3.  Attach black and green wire to TH/TP and TH terminal on 
valve.
4.  Attach cover plate to valve bracket with two (2) 8 x 1/2" Truss 
-head Phillips screws.
Millivolt)  thermopile  is  self  powered  gas  valve  and  does  not 
require 110 volts. See Figure 10 to provide optional wall switch, 
thermostat, or remote control. Maximum length of 20 feet of 
16 AWG  to  conductor  wires  is  to  be  used  with  all  optional 
switches.
Use  the  two  leads  (black/red  wires  and  brown  wires)  from 
REMOTE/ON/OFF switch to attach optional components.
Check System Operation
Millivolt system and all individual components may be checked 
with a millivolt meter 0-1000 MV range.
Remote Receiver
Figure 10
1.  The remote receiver can be placed behind the gas valve on 
under side of chimenea.
2.  Attach remote receiver to the flat bottom of casing behind gas 
valve on underside of chimenea.
Refer to remote control installation and operating instructions for 
more details on remote control.
750 Millivolt System
When you ignite the pilot, the thermocouple produces millivolts 
(electrical current) which energizes the magnet in the gas valve. 
After 30 seconds to 1 minute time period you can release the gas 
control knob and the pilot will stay ON. Allow your pilot flame to 
operate an additional one (1) to two (2) minutes before you turn the 
gas control knob from the PILOT position to the ON position. This 
time period allows the millivolts (electrical current) to buildup to 
a sufficient level allowing the gas control to operate properly.   
Millivolt Control
The valve regulator controls the burner pressure which should be 
checked at the pressure test point. Turn captured screw counter 
clockwise 2 or 3 turns and then place tubing to pressure gauge 
over test point (Use test point “A” closest to control knob). After 
taking pressure reading, be sure and turn captured screw clockwise 
firmly to re-seal. Do not over torque. Check for gas leaks.