Empire Comfort Systems CHBR-16-3 User Manual

Page of 20
Page 3
16934-3-0806
When  used  without  adequate  combustion  and  ventilation  air, 
heater  may  give  off  CARBON  MONOXIDE,  an  odorless, 
poisonous gas.
Do not install heater until all necessary provisions are made 
for  combustion  and  ventilation  air.  Consult  the  written 
instructions  provided  with  the  heater  for  information 
concerning combustion and ventilation air. In the absence 
of instructions, refer to the National Fuel Gas Code, ANSI 
Z223.1, Section 5.3 or applicable local codes.
This  heater  is  equipped  with  a  PILOT  LIGHT  SAFETY 
SYSTEM designed to turn off the heater if not enough fresh air 
is available.
DO  NOT  TAMPER  WITH  PILOT  LIGHT  SAFETY 
SYSTEM!
If heater shuts off, do not relight until you provide fresh air.
If heater keeps shutting off, have it serviced. Keep burner and 
control compartment clean.
CARBON MONOXIDE POISONING MAY LEAD TO 
DEATH.
Early signs of carbon monoxide poisoning resemble the flu, with 
headache, dizziness and/or nausea. If you have these signs, heater 
may not be working properly. Get fresh air at once! Have heater 
serviced.
Some  people  –  pregnant  women,  persons  with  heart  or  lung 
disease, anemia, those under the influence of alcohol, those at high 
altitudes – are more affected by carbon monoxide than others.
The pilot light safety system senses the depletion of oxygen at 
its location. If this heater is installed in a structure having a high 
vertical dimension, the possibility exists that the oxygen supply 
at the higher levels will be less than that at the heater. In this type 
of application, a fan to circulate the structure air will minimize 
this effect. The use of this fan will also improve the comfort level 
in the structure. When a fan is used to circulate air, it should be 
located so that the air flow is not directed at the burner.
•  An unvented room heater having an input rating of more than 
10,000 Btu per hour shall not be installed in a bedroom or 
bathroom.
•  An unvented room heater having an input rating of more than 
6,000 Btu per hour shall not be installed in a bathroom.
•  Never burn solid fuels in a fireplace where a gas log set is 
installed.
•  Due to high temperatures, the appliance should be located out 
of traffic and away from furniture and draperies.
•  Do not place clothing or other flammable material on or near 
the appliance.
•  Children and adults should be alerted to the hazards of high 
surface temperature and should stay away to avoid burns or 
clothing ignition.
•  Young children should be carefully supervised when they are 
in the same room as the appliance.
•  This unit complies with ANSI Z21.11.2 Unvented Heaters.
•  Correct installation of ceramic fiber logs, proper location of 
the heater and annual cleaning are necessary to avoid potential 
problems  with  sooting.  Sooting,  resulting  from  improper 
installation or operation, can settle on surfaces outside the 
fireplace.
•  Avoid any draft s that could alter burner flame patterns. Do 
not allow fans to blow directly into the fireplace. Do not place 
a blower inside of firebox. Ceiling fans may create drafts that 
alter burner flame patterns. Sooting and improper burning will 
occur as a result of drafts.
•  The  installation  must  conform  with  local  codes  or,  in  the 
absence of local codes, with the National Fuel Gas Code, ANSI 
Z223.1 (latest edition) and to the National Electrical Code, 
ANSI/NFPA70 (latest edition).
•  NOTE: Installation and repair should be done by a qualified 
service  person. The  appliance  should  be  inspected  before 
use and at least annually by a qualified service person. More 
frequent cleaning may be required due to excessive lint from 
carpeting, bedding material, etc. It is imperative that the control 
compartment, burners and circulating air passageways of the 
appliance be kept clean.
•  Any safety screen or guard removed for servicing an appliance 
must be replaced prior to operating the appliance. Provide 
adequate combustion and ventilation air.
•  The flow of combustion and ventilation air MUST NOT be 
obstructed.
•  Provide  adequate  clearances  around  air  openings  into  the 
combustion chamber and adequate accessibility clearance for 
servicing  and  proper  operation.  NEVER  obstruct  the  front 
opening of the appliance.
•  A  fireplace  screen  must  be  in  place  when  the  appliance  is 
operating and, unless other provisions for combustion air are 
provided, the screen shall have an opening(s) for introduction 
of combustion air.
•  WARNING:  Do  not  allow  fans  to  blow  directly  into  the 
fireplace. Avoid any drafts that alter burner flame patterns.
•  WARNING: Do not use a blower insert, heat exchanger insert 
or other accessory not approved for use with heater.
IMPORTANT SAFETY INFORMATION
WARNING