Empire Comfort Systems CHBR-16-3 User Manual

Page of 20
Page 5
16934-3-0806
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment 
or  accessories  and  repair  and  servicing  of  equipment  shall  be 
performed only by a qualified agency. The term "qualified agency" 
means any individual, firm, corporation, or company that either in 
person or through a representative is engaged in and is responsible 
for (a) the installation, testing, or replacement of gas piping or (b) the 
connection, installation, testing, repair, or servicing of equipment; 
that is experienced in such work; that is familiar with all precautions 
required, and that has complied with all the requirements of the 
authority having jurisdiction.
State  of  Massachusetts:  The  installation  must  be  made  by 
a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental 
room heaters shall provide to each purchaser a copy of 527 CMR 
30 upon sale of the unit.
In the State of Massachusetts the CHBR-16 must be secured 
to the floor.
The installation must conform with local codes or, in the absence 
of local codes, with the National Fuel Gas Code, ANSI Z223.1.*
*Available from the American National Standards Institute, Inc. 11 West 42nd St., 
New York, N.Y. 10018.
IMPORTANT:  Read  all  instructions  carefully  before  starting 
installation. Failure to follow these installation instructions may 
result in a possible fire hazard and will void the warranty.
Save this manual for future reference.
Please  read  this  manual  before  installing  and  using  the 
appliance.
Instructions to Installer
1.  Installer  must  leave  instruction  manual  with  owner  after 
installation.
2.  Installer must have owner fill out and mail warranty card supplied 
with unvented room heater.
3.  Installer should show owner how to start and operate unvented 
room heater.
Always  consult  your  local  Building  Department  regarding 
regulations, codes or ordinances which apply to the installation 
of an unvented room heater.
This appliance may be installed in an aftermarket* manufactured 
(mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from 
the manufacturer.
This appliance is only for use with the type of gas indicated on 
the  rating  plate. This  appliance  is  not  convertible  for  use  with 
other gases.
Any alteration of the original design, installed other than as shown 
in these instructions or use with a type of gas not shown on the 
rating plate is the responsibility of the person and company making 
the change.
INTRODUCTION
SPECIFICATIONS
Manifold Pressure
Natural Gas
Propan Gas
Regulator pressure setting 3.5" W.C.
Regulator pressure setting
10.0" W.C.
Gas inlet pressure
Max. 10.5" W.C. Gas inlet pressure
Max 13.0" W.C.
Min. 5.0" W.C.
Min. 11.0" W.C.
Model
CHBR-16
Input    Maximum Btu/Hr
             Minimum Btu/Hr
20,000
14,000
Height
49"
Width
23"
Gas Inlet
3/8"
ACCESSORIES
Product 
No.
Description
CHG-VF
Antique Green Chimenea
CHR-VF
Terra Cotta Red Chimenea
FRBC-1
Battery Operated Remote Control
FRBTC-1
Battery Operated Remote Control with Thermo-
stat
FREC-1
Electri Remote Control
FWS-1
Wall Switch