Desa RL2718PA/NA User Manual

Page of 40
www.desatech.com
113097-01E
7
TROUBLESHOOTING
Continued 
 WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your 
building.
•  Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
 Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, 
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These 
fumes may mix with combustion air and create odors. These odors will disappear over time.
POSSIBLE CAUSE
1. Heater burning vapors from 
paint, hair spray, glues, clean-
ers,  chemicals,  new  carpet, 
etc. (See IMPORTANT state-
ment above)
2. Gas  leak.  See  Warning 
statement above
1. Not enough fresh air is avail-
able
2. Low line pressure
3. ODS/pilot  is  partially 
clogged
1. Gas  leak.  See  Warning 
statement above
2. Control valve defective
1. Foreign matter between con-
trol valve and burner
2. Gas  leak.  See  Warning 
statement above
1. Thermostat sensing bulb needs 
to be repositioned
REMEDY 
1. Open window and ventilate 
room. Stop using odor caus-
ing products while heater is 
running
2. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 14)
1. Open window and/or door for 
ventilation
2. Contact local propane/LP or 
natural gas company
3. Clean ODS/pilot (see Cleaning 
and Maintenance, page 23)
1. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 14)
2. Replace control valve
1. Take  apart  gas  tubing  and 
remove foreign matter
2. Locate and correct all leaks 
(see Checking Gas Connec-
tions, page 14)
1. Reposition thermostat sensing 
bulb (see Optional Positioning 
of Thermostat Sensing Bulb, 
beginning on page 28
OBSERVED pROBLEM
Heater  produces  unwanted 
odors
Heater  shuts  off  in  use  
(ODS  operates)  temperature 
drops to a lower than ideal level 
before log set comes back on 
Gas  odor  even  when  control 
knob is in OFF position
Gas odor during combustion
Logs  set  cycles  to  pilot,  but 
room