TriStar SP3010X15AZ User Manual

Page of 15
WWW.HAYWARDPOOL.COM              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 
TriStar
 Pump Series__________             _____                ______________________________ Page 5 of 15 
 
Product Specifications 
 
 
Installation Instructions 
 
 WARNING –
 
This product should be installed and serviced only by a qualified professional.
 
 
 
 
 
 
  
 
Pump Location 
 
 
 
 
 
  
 
 
Locate filter as close to pool as practical and run suction lines as direct as possible to reduce friction 
loss.  Suction lines should have continuous slope upward from lowest point in line.  Joints must be tight 
(but not over-tightened).  Suction line diameter must equal or be larger than the discharge line diameter. 
 
Though the filter is designed for outdoor use, it is strongly advised to place pump and filter in the shade 
to shield them from continuous direct heat.  Select a well-drained area that will not flood when it rains.  Do NOT install 
pump and filter in a damp or non-ventilated location.  
Keep motor clean.  Pump motors require free circulation of air for 
cooling.   
 
Pump Mounting 
 
Install pump on a firm, level base or pad to meet all local and national codes.  Fasten pump to base or pad with screws or 
bolts to further reduce vibration and stress on pipe or hose joints.  The base MUST be solid, level, rigid, and vibration free.   
 
 
Pump mount must: 
  Allow pump inlet height to be as close to water level as possible.
 
 
  Allow use of short, direct suction pipe (to reduce friction losses). 
  Allow for gate valves in suction and discharge piping. 
  Be protected from excess moisture and flooding. 
  Allow adequate access for servicing pump and piping.   
 
Pipe Sizing Chart 
 
* NOTE - It is recommended that a minimum length of straight piping (shown as “L” in above diagram), equivalent 
to 5 pipe size diameters, be used between the pump suction inlet and any plumbing fittings (elbows, valves, etc.). 
 
HP FR 
“A” MR 
“A” 
½  
13 5/8” 
¾  
13 7/8” 
13 3/8” 
14 3/8” 
13 7/8” 
1 * 
14 3/8” 
1 ½  
14 7/8” 
13 7/8” 
1 ½ * 
14 7/8” 
14 3/8” 
14 7/8” 
15 1/8” 
2 * 
14 7/8” 
14 7/8” 
2 ½  
14 7/8” 
2 ½ * 
14 7/8” 
17 1/8” 
15 5/8” 
3 ** 
14 1/2” 
MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE 
Pipe Size 
[mm] 
Flow Rate 
GPM [LPM] 
Suction Pipe 
Length * 
Pipe Size 
[mm] 
Flow Rate 
GPM [LPM] 
Suction Pipe 
Length * 
Pipe Size 
[mm] 
Flow Rate 
GPM [LPM] 
Suction Pipe 
Length * 
1”  [32] 
20  [75] 
5” 
1 ½”  [50] 
45  [170] 
7 ½”  
2 ½”  [75] 
110  [415] 
12 ½”  
1 ¼”  [40] 
30  [110] 
6 ¼”  
2”  [63] 
80  [300] 
10” 
3”  [90] 
160  [600] 
15” 
*      Two-Speed Pump 
** Three-Phase 
Pump