Pump Mounting (cont’d.)
 
 
 
 WARNING –
 
Hazardous Pressure.  Pumps, filters, and other equipment/ components of a 
swimming pool filtration system operate under pressure.  Incorrectly installed and/or improperly tested 
filtration equipment and/or components may fail resulting in severe personal injury or death.
 
 
 
Plumbing 
 
Use Teflon tape to seal threaded connections on molded plastic components.  All plastic fittings must be new or thoroughly 
cleaned before use.  NOTE - Do NOT use Plumber’s Pipe Dope as it may cause cracking of the plastic components.  
When applying Teflon tape to plastic threads, wrap the entire threaded portion of the male fitting with one to two layers of 
tape.  Wind the tape clockwise as you face the open end of the fitting, beginning at the end of the fitting.  The pump suction 
and outlet ports have molded-in thread stops.  Do NOT attempt to force hose connector fitting past this stop.  It is only 
necessary to tighten fittings enough to prevent leakage.  Tighten fitting by hand and then use a tool to engage fitting an 
additional 1 ½ turns.  Use care when using Teflon tape as friction is reduced considerably; do NOT over-tighten fitting or 
you may cause damage
.  If leaks occur, remove connector, clean off old Teflon tape, re-wrap with one to two additional 
layers of Teflon tape, and re-install connector.
 
 
Fittings restrict flow.  For better efficiency, use the fewest possible fittings (but at least two suction outlets).  Avoid fittings 
that could cause an air trap.  Pool and spa fittings MUST conform to the International Association of Plumbing and 
Mechanical Officials (IAPMO) standards.
  
Use a non-entrapping suction fitting in pool (multiple drains) or double suction 
(skimmer and main drain).   
 
Electrical 
 
 
 
WARNING –
 
Ground and bond motor before connecting to electrical power supply.  Failure 
to ground and bond pump motor can cause serious or fatal electrical shock hazard.
  
Do NOT ground to 
a gas supply line.
  
To avoid dangerous or fatal electrical shock, turn OFF power to motor before 
working on electrical connections.
  
Ground Fault Circuit Interrupter (GFCI) tripping indicates electrical 
problem.  If GFCI trips and won’t reset, consult electrician to inspect and repair electrical system.
  
Fire 
Hazard - match supply voltage to motor nameplate voltage.
  
Insure that the electrical supply 
available agrees with the motor’s voltage, phase, and cycle, and that the wire size is adequate for the HP 
(kW) rating and distance from the power source.  NOTE - All electrical wiring MUST be performed by a licensed 
electrician, and MUST conform to local codes and NEC regulations.  
Use copper conductors only. 
 
 
Motor Brake Horsepower 
Motor Rated Horsepower 
Motor Electric V/A 
Wire Size / Breaker 
HP  (kW) 
HP  (kW) 
Voltage 
Amps 
AWG 
Amps 
1.13  (0.84) 
0.50  (0.37) 
208 - 230 / 115 
5.3 - 4.9 / 9.8 
14 
10 / 15 
1.39  (1.04) 
0.75  (0.56) 
208 - 230 / 115 
7.0 - 6.2 / 12.4 
14 
10 / 15 
1.85  (1.38) 
1.00  (0.75) 
208 - 230 / 115 
8.5 - 7.4 / 14.8 
14 / 12 
15 / 20 
2.40  (1.79) 
1.50  (1.12) 
208 - 230 / 115 
11.2 - 10.2 / 20.4 
14 / 10 
15 / 30 
2.70  (2.01) 
2.00  (1.49) 
208 - 230 
11.8 - 11.0 
14 
15 
3.60  (2.69) 
3.00  (2.24) 
208 - 230 
16.0 - 14.8 
12 
20 
3.60  (2.69) * 
3.00  (2.24) * 
208 - 230 / 460 * 
9.6 - 9.4 / 4.7 * 
14 * 
15 / 10 * 
1.85 / 0.22  (1.38 / 0.16) 
1.00 / 0.12  (0.75 / 0.09) 
208 - 230 
8.6 - 8.2 ¹ 
14 
15 
2.40 / 0.28  (1.79 / 0.21) 
1.50 / 0.18  (1.12 / 0.13) 
208 - 230 
11.4 - 10.4 ² 
14 
15 
Full R
at
e Pumps 
2.70 / 0.33  (2.01 / 0.25) 
2.00 / 0.25  (1.49 / 0.19) 
208 - 230 
12.4 - 11.2 ³ 
14 
15 
0.94  (0.70) 
0.75  (0.56) 
230 / 115 
5.4 / 10.8 
14 
10 / 15 
1.25  (0.93) 
1.00  (0.75) 
230 / 115 
7.0 / 14.0 
14 
10 / 15 
1.65  (1.23) 
1.50  (1.12) 
230 / 115 
7.7 / 15.4 
14 / 12 
10 / 20 
2.20  (1.64) 
2.00  (1.49) 
230 / 115 
10.8 / 21.6 
14 / 10 
15 / 30 
2.60  (1.94) 
2.50  (1.86) 
230 
11.5 
14 
15 
3.45  (2.57) 
3.00  (2.24) 
230 
13.5 
14 
15 
1.85 / 0.22  (1.38 / 0.16) 
1.50 / 0.18  (1.12 / 0.13) 
208 - 230 
8.6 - 8.2 ¹ 
14 
15 
2.40 / 0.28  (1.79 / 0.21) 
2.00 / 0.25  (1.49 / 0.19) 
208 - 230 
11.4 - 10.4 ² 
14 
15 
Ma
x Ra
te
 Pum
ps 
2.70 / 0.33  (2.01 / 0.25) 
2.50 / 0.31  (1.86 / 0.23) 
208 - 230 
12.4 - 11.2 ³ 
14 
15 
¹
²
³  Low Speed Amps:  (¹ 2.8 - 3.0) (² 3.2 - 3.4) (³ 3.8 - 4.1) 
*      Three-Phase (3Φ) Pump - motor starter required