THEORY OF OPERATION
The  Fuel  System:
 The hose/regulator assembly 
attaches to the propane gas supply. The propane 
gas moves through the automatic control valve 
and out the nozzle.
The Air  System:
 The motor turns the fan. The 
fan pushes air into and around the combustion 
chamber. This air is heated and provides a stream 
of clean, hot air.
Air For Combustion 
And Heating
Fuel
Combustion Chamber
Figure 2 - Cross Section Operational View (Heater may vary from illustration)
Clean 
Heated 
Air Out 
(Front)
Cool 
Air In 
(Back)
Fan
Motor
Power Cord
Hose/Regulator 
Assembly
Nozzle
The Ignition System:
 The spark transformer and 
spark plug lights the main burner
The Safety Control System:
 This system causes 
the heater to shut down if the flame goes out.
Note:
 Some parts are located differently on some 
models.
PROPANE SUPPLY
Propane gas and propane tank(s) are to be fur-
nished by the user.
Use  this  heater  only  with  a  propane  vapor 
withdrawal supply system. See Chapter 5 of the 
Standard for Storage and Handling of Liquefied 
Petroleum Gas, ANSI/NFPA 58
. Your local library 
or fire department will have this booklet.
The amount of propane gas ready for use from 
propane  tanks  varies. Two  factors  decide  this 
amount:
1.  The amount of propane gas in tank(s)
2.  The temperature of tank(s)
The chart below shows the number of 100 pound 
(45 kg) tanks needed to run this heater.
 
 
Number of tanks
 
Temperature 
Models
 
at tank location 
55  85 
125
 
above 20° F (-7° C) 
1  1 
2
  20° F (-7° C) to -0 (-18° C)  1  2 
3
  below -0° F (-18° C) 
2  2  (Use larger
 
 
 
 
tank)
Less gas is vaporized at lower temperatures. You 
may need two or more 100 pound (45 kg) tanks 
or one larger tank in colder weather. Your local 
propane gas dealer will help you select the proper 
supply system. The minimum surrounding-air tem-
perature rating for each heater is -20° F (-29° C).
INSTALLATION
 WARNING: Review and un-
derstand  the  warnings  in  the 
Safety Information section, page 
2. They are needed to safely op-
erate this heater. Follow all local 
codes when using this heater.
 WARNING: Test all gas piping 
and connections for leaks after 
installing or servicing. Never use 
an open flame to check for a leak. 
Apply a mixture of liquid soap 
and water to all joints. Bubbles 
forming show a leak. Correct all 
leaks at once.