1.  Provide propane supply system (see Propane 
Supply, page 4).
2.  Connect  fuel  gas  connector  fitting  on 
hose/regulator assembly to propane tank(s). 
Turn  counterclockwise  into  threads  on 
tank valve. Tighten firmly using wrench. 
IMPORTANT:
 Tighten regulator with vent 
pointing down. Pointing vent down protects 
regulator from weather damage.
3.  Connect  hose  to  inlet  connector. Tighten 
firmly using a wrench. IMPORTANT: Extra 
hose or piping may be used if needed. Install 
extra hose or piping between hose/regulator 
assembly and propane tank. You must use the 
regulator supplied with heater.
4.  Open propane supply valve on propane tank(s) 
slowly. Note: If not opened slowly, excess-
flow check valve on propane tank may stop 
gas flow. If this happens, close propane supply 
valve and open again slowly.
5.  Check all connections for leaks.
6.  Close propane supply valve.
INSTALLATION
Continued
Figure 4 - Hose and Inlet Connector 
(Heater may vary from illustration)
Hose
Inlet Connector
Figure 3 - Regulator With Vent Pointing 
Down
Propane 
Tank
Hose
Regulator
Vent 
(pointing 
down)
Fuel Gas 
Connector
Supply 
Valve
VENTILATION
 WARNING: Follow the mini-
mum fresh, outside air ventila-
tion  requirements.  If  proper 
fresh, outside air ventilation is 
not provided, carbon monoxide 
poisoning  can  occur.  Provide 
proper fresh, outside air ventila-
tion before running heater.
Provide a fresh air opening of at least three square 
feet for each 100,000 Btu/Hr (105,500 k/j) rat-
ing. Provide extra fresh air if more heaters are 
being used.
OPERATION
 WARNING: Review and un-
derstand  the  warnings  in  the 
Safety Information section, page 
2. They are needed to safely op-
erate this heater. Follow all local 
codes when using this heater.
TO START HEATER
1.  Follow all installation, ventilation and safety 
information.
2.  Locate  heater  on  stable  and  level  surface. 
Make sure strong drafts do not blow into front 
or rear of heater.
3.  Plug power cord of heater into a three-prong, 
grounded extension cord. Extension cord must 
be at least six feet (1.83 m) long, UL/CSA 
listed and of a proper size.
 
Extension Cord Size Requirement
 
Up to 100 feet (30.5 m) long, use 16 AWG 
rated cord.
 
101 to 200 feet (30.78 to 61 m) long, use 14 
AWG rated cord.
4.  Plug extension cord into a 120 volt/60 hertz, 
three-hole, grounded outlet. Motor will start. 
Fan will turn, forcing air out front of heater.
5.  Open  propane  supply  valve  on  propane 
tank(s) slowly. Note: If not opened slowly, 
excess-flow check valve on propane tank will 
stop gas flow. You may hear a click from the 
excess-flow check valve closing. If this hap-
pens, reset the excess-flow check valve by 
closing propane supply valve and open again 
slowly.