Carrier 48SS024 User Manual

Page of 8
CERTIFIED DIMENSION PRINT
OUTDOOR COIL
INDOOR COIL
INDOOR COIL ACCESS
REQ’D CLEARANCES FOR SERVICING — in. (mm)
Duct Panel . . . . . . . . . . . . . . . . . . . . . . . . 0
Unit Top . . . . . . . . . . . . . . . . . . . . . 36 (914.4)
Side Opposite Ducts . . . . . . . . . . . . . . 36 (914.4)
Compressor Access
. . . . . . . . . . . . . . 36 (914.4)
(Except for NEC requirements)
REQ’D CLEARANCES TO COMBUSTIBLE MAT’L
— in. (mm)
Maximum Extension of Overhangs . . . . . . 48 (1219.2)
Unit Top . . . . . . . . . . . . . . . . . . . . . 14 (355.6)
Duct Side of Unit
. . . . . . . . . . . . . . . . . 2 (50.8)
Side Opposite Ducts . . . . . . . . . . . . . . 14 (355.6)
Bottom of Unit
. . . . . . . . . . . . . . . . . . . . . . 0
Flue Panel
. . . . . . . . . . . . . . . . . . . 36 (914.4)
NEC (National Electrical Code) REQ’D CLEARANCES
— in. (mm)
Between Units, Control Box Side . . . . . . . 42 (1066.8)
Unit and Ungrounded Surfaces,
Control Box Side
. . . . . . . . . . . . . . . 36 (914.4)
Unit and Block or Concrete Walls and Other
Grounded Surfaces, Control Box Side
. . . 42 (1066.8)
UNIT
48SS
ELECTRICAL
CHARACTERISTICS
UNIT
WEIGHT
CORNER WEIGHT
(lb/kg)
lb
kg
A
B
C
D
018040
208/230-1-60
272
123
81/37
62/28
76/35
53/24
024040
208/230-1-60
303
138
97/44
43/20
123/56
40/18
024060
208/230-1-60
315
143
100/45
46/21
126/57
43/20
030040
208/230-1-60
320
145
100/45
47/21
126/57
47/21
030060/080
208/230-1-60
324
147
94/43
63/29
115/52
52/24
036060/080
208/230-1-60
336
153
86/39
76/35
111/50
63/29
036100/120
208/230-1-60
348
158
89/40
79/36
114/52
66/30
042060/080
208/230-1-60
375
170
95/43
86/39
119/54
75/34
042100/120
208/230-1-60
387
176
98/45
89/40
122/55
78/35
UNIT
48SS
UNIT
HEIGHT
(in./mm)
DIMENSION
(in./mm)
CENTER OF GRAVITY
(in./mm)
E
F
G
X
Y
Z
018040
24.12/612.8
16
9
16
/420.7
18
15
16
/481.0
25.07/637
20.59/523
10.85/276
024040
24.12/612.8
16
9
16
/420.7
18
15
16
/481.0
27.07/688
23.35/693
10.85/276
024060
24.12/612.8
16
9
16
/420.7
18
15
16
/481.0
26.98/685
23.27/591
10.85/276
030040
24.12/612.8
16
9
16
/420.7
18
15
16
/481.0
26.71/678
23.46/596
10.85/276
030060/080
24.12/612.8
16
9
16
/420.7
18
15
16
/481.0
27.15/689
22.36/568
10.85/276
036060/080
24.12/612.8
16
9
16
/420.7
18
15
16
/481.0
27.50/698
22.48/571
10.85/276
036100/120
24.12/612.8
16
9
16
/420.7
18
15
16
/481.0
27.40/696
22.44/570
10.85/276
042060/080
28.12/714.2
20
9
16
/522.3
22
15
16
/582.6
27.01/686
22.44/570
12.65/321
042100/120
28.12/714.2
20
9
16
/522.3
22
15
16
/582.6
26.94/684
22.44/570
12.65/321
NOTE: Clearances must be maintained to prevent recircu-
lation of air from outdoor fan discharge.
3