Burnham 1100-H4 User Manual

Page of 96
8
III.  Venting / Air Intake Piping
TABlE 1:  AIR INTAkE / VENT SySTEM OPTIONS
WARNING
Do not use this boiler with galvanized, Type 04 or Type 1 stainless steel, non metallic or any other 
non Al9-4C
®
 based vent systems.
Do not use a barometric damper or drafthood with this appliance.
Do not use vent dampers with this boiler.
Moisture and ice may form on surfaces around termination.  To prevent deterioration, surfaces should 
be in good repair (sealed, painted, etc.).
This appliance needs fresh air for safe operation and must be installed so there are provisions for 
adequate combustion and ventilation air.
Do not reduce size of air intake pipe.
Read, understand and follow combustion air instruction restrictions contained in the Pre-Installation 
instructions of this manual.
Do not operate appliance where gasoline or other flammable vapors or liquids, or sources of hydro-
carbons (i.e. bleaches, cleaners, chemicals, sprays, paint removers, fabric softeners, etc.) are used, 
stored and/or present in the air.
When installing vent pipe through chimney, no other appliance can be vented into the chimney.
Do not exceed maximum vent/air intake lengths.  Refer to Table 4.
Option
Description
Additional 
Vent Kit 
Required
Part Number
Installation 
Drawing and 
Specification 
(See Section)
1.  Separate
     Horizontal  
Direct Vent (sealed combustion) with both the vent pipe and 
air intake pipe terminating horizontally (through a sidewall) 
with individual penetrations for the vent and air intake piping 
and terminals.
No
See Table 2
D.
2.  Separate 
     Vertical
Direct Vent (sealed combustion) with both the vent pipe and 
air intake pipe terminating vertically (through the roof) with 
individual penetrations for the vent and air intake piping and 
terminals.
No
See Table 2
E.
3.  Combination    
     Horizontal
Direct Vent (sealed combustion) with the vent pipe and air 
intake  pipe  joining  at  a  common  terminal  and  terminating 
horizontally  (through  a  sidewall  up  to  15”  thick)  with  only 
one penetration.
Yes
3 - 6 Section 
(61106012)
F.
4.  Combination    
     Vertical  
Direct Vent (sealed combustion) with the vent pipe and air 
intake  pipe  joining  at  a  common  terminal  and  terminating 
vertically (through the roof) with only one penetration.
Yes
3 - 4 Section
(100222-01)
5 - 6 Section
(100223-01)
G.
5.  Indoor Air
Power Vent - Air used for combustion is provided from within 
the building.
No
-----
H.
6.  Optional
     Separate
     Horizontal
Direct Vent (sealed combustion) with both the vent pipe and 
air intake pipe terminating horizontally (through a sidewall) 
with individual penetrations for the vent and air intake piping 
and terminals.
No
See Table 2
I.