Troubleshooting Chart for CWI Boilers Without Tankless Heaters
Caution
: Read page 36 before attempting to use this chart
37
Boiler  
Equipped 
With 
Damper?
Thermostat 
calls for heat
Circulator 
start?
120 volts 
at L1&L2?
120 volts at 
C1&C2?
N
N
*Pow er off
*Blow n fuse or 
tripped breaker
*Misw ired or      
loose electrical 
connection in  
120V line
Remove t'stat or 
zone valve end 
sw itch w ires from 
T&TV terminals on 
L8148E.  Install 
temporary jumper 
across terminals  T 
and TV
Does 
circulator 
run now ?
*Defective 
L8148E-see 
Note 6 on page 
36.
*Loose connection in t'stat or 
zone valve end sw itch w iring
*Defective t'stat or zone valve 
end sw itch
*T'stat or zone system 
misw ired-consult  t'stat or 
zone valve manufacturer's 
instructions
Vent 
damper 
open?
24 volts
across B and R 
(limit sw itch) in 
L8148E ?
*Boiler off on 
 limit
*Defective 
 high limit.
24 volts 
betw een pins
 1&(blue&yellow )and 
2&4 (orange&yellow ) on 
damper end of damper 
harness? See 
Note 7 on page 28.
Loose 
connection 
betw een 
damper 
harness and 
L8148E
*Defective 
damper 
harness.
* Defective 
L8148E
*Obstruction in 
path of damper 
blade 
*Defective 
damper motor
*Loose 
connection 
betw een damper 
harness and 
damper
Y
START
24 volts 
across 
T&TV?
120 volts 
across 
terminals at 
circulator?
*Seized or 
defective 
circulator
*Bad electrical 
connection 
betw een C1 or 
C2 and 
circulator
N
     Y
       N
Y
N
Y
      Y
Y
    N
N
Y
N
Y
Y
N
Y
N