Cape Cod Wood Stove
R
INSTALLATION
BLOWER INSTALLATION & OPERATION
ADJUSTING THE BLOWER SPEED
 CONTROL, IF NECESSARY*
NOTE:   When  the  speed  control  is  turned  clockwise,  it 
will click on to high speed.  Turn the speed control 
clockwise to decrease the speed.  At full clockwise, 
the blower should blow gently, but should not stop.
1.    With the unit plugged in, turn the speed control knob 
to slow (full clockwise).
2.    With a small screwdriver, adjust the blower speed by 
turning the adjustment mechanism through the hole 
on the side of the speed control.
3.    Adjust the speed so the blower runs slowly, but does 
not  stop.   Turn  clockwise  to  slow  the  blower  and 
counterclockwise to increase the speed.
*The blower speed control for this unit is adjusted 
at  the  factory,  and  normally  does  not  require 
further adjustment.  
Part 831-1700
The blower is shipped fully assembled 
and ready for installation.
1.  Remove  the  three  Phillips  head  screws  and 
the mounting bar from the outer shield at the 
lower back of the stove.
2.  Align  holes  in  mounting  bar  with  those  on 
mounting plate of blower in order to sandwich 
the  blower  mounting  plate  between  the  rear 
shield  and the mounting bar.  
3.  Align  screws  with  holes  in  rear  shield  and 
tighten, securing blower to stove.
4.  Do  not  remove  ground  prong  from  plug.  
Plug blower cord into a grounded outlet.  Route 
power cord away from stove in such a manner 
to avoid heat from the stove, traffic, or other 
damage.   Do  not  route  cord  over  or  in  front 
of stove.
BLOWER OPERATING INSTRUCTIONS
1.  Initial  (cold)  start-up:    Leave  blower  off 
until your stove is hot and a good coalbed 
is  established.   The  blower  can  be  turned 
on  approximately  30  minutes  after  loading 
the stove with fuel.
2.  High burn setting:  The blower may be left 
on throughout the burn.
3.  Medium burn setting:  The blower should 
be left off until a good burn is established, 
then turned on at a medium or high rate.
4.  Low burn setting:  The blower tends to cool 
off  the  stove.   Leave  blower  off  until  burn 
is  well  established.   Then  turn  on  at  your 
desired rate.
5.  The  highest  blower  speed  is  obtained  by 
turning  the  speed  control  on  and  then 
adjusting back towards off as far as possible 
without  turning  the  blower  off.   For  a  low 
blower speed, turn the control knob clockwise 
as far as possible.
Blower 
mounting 
plate
Rear 
Shield
Mounting 
bar