Sherwood EG40 DV User Manual

Page of 39
Initial Installation
QUALIFIED INSTALLERS ONLY
18
16. Slide the 90° elbow over the flex pipe. Do not slip the outer sections of pipe together, you will 
require some movement in these pipe section in order to secure the flex pipe to the flue 
outlet on the appliance.
17. Stretch the flex liner to a length long enough to ensure the flex liner can be easily connected to the 
flue outlet of the appliance. 
18. Install the remaining wire spacers over the flexible liner and install the vertical section of pipe. Ensure 
the wire spacers are positioned at either end of the pipe (refer to Figure 19 and 20).
19. Place a bead of high temperature silicone on the flue pipe and slide the flex liner over the collar, 
secure the flex liner with three (3) sheet metal screws evenly spaced. 
20. Align all straight sections of pipe, slipping all joints together and installing with three (3) sheet metal 
screws evenly spaced. 
21. Install the brass decorative rings around each joint making sure this decorative ring covers the sheet 
metal screws that secure each section of pipe together and secure to vent pipe in the slotted tab on 
the backside of the pipe so that the fastener would not be seen.
22. Secure the horizontal section of pipe to the inside finished collar by installing a screw in the tab on 
the inside finished collar. This will prevent the pipe from being disconnected at the vent terminal.
23. Light the appliance and ensure proper operation.
O
THER
 A
PPROVED
 V
ENT
 P
ARTS
:
Table 3: Approved Vent Manufacturers
Manufacturer
Trade Name
Nominal Sizes
American Metal Products
AmeriVent Direct
4” - 6 5/8”
Security Chimneys International LTD
Secure Vent
4” - 6 5/8”
Selkirk Metalbestos
Direct-Temp
4” - 6 5/8”
Simpson Dura-Vent
Direct Vent GS
4” - 6 5/8”
The  EG40DV  fireplace  has  been  tested  and  certified  for  use  with  AMERICAN  METAL  PRODUCTS 
“AMERIVENT DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES.  SECURITY CHIMNEY’S 
“SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available 
for  horizontal  and  vertical  venting.    When  using  Simpson  Duravent,  it  is  recommended  that,  before 
installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-
Pac to each inner joint.  When planning an installation, it will be necessary to select the proper length of 
vent pipe for the particular requirements.  
WARNING: Do not mix parts from different vent manufacturers’ systems.
EXCEPTION  TO WARNING:    This product  has  been  evaluated by  Intertek  for  using a  Direct  Vent  GS 
starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems.  Use 
of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the 
Intertek WH listing of the appliance.