Sherwood EG40 DV User Manual

Page of 39
V
ENTING
 
INTO
 
A
 C
LASS
 ‘A’ C
HIMNEY
:
This model is also certified and tested to vent into CLASS ‘A’ wood stove chimneys.
Place the freestanding direct vent appliance in the desired location.
Use  a  conversion  kit  from  Simpson  Duravent  (931,  932,  or  933),  or  Security  Chimney  (SV4CCK1, 
SV4CCK2, or SV4CCK1). Which kit is used will depending on the inner diameter of the CLASS ‘A’ chimney 
that this appliance is to be vented into.
Place a bead of high temperature silicone or Mil-Pac at each 
connection to ensure a tight seal.
NOTE:  An  approved  4”  (10  cm)  diameter  flex  liner  must  be 
used in the application.
NOTE: Use Simpson Dura Vent from the top of the appliance 
until this vent reaches the CLASS ‘A’ chimney. Install the retro 
adapter to the top section of GS direct vent pipe and install the 
flex liner to the retro adapter. 
Fully line the CLASS ‘A’ chimney with a minimum 4” (10 cm) 
flex liner to the top of the CLASS ‘A’ chimney.
Place a bead of high temperature silicone to the Simpson Cap 
adapter and securely attach the flex liner to the adapter.
Secure the cap adapter to the CLASS ‘A’ chimney ensuring an 
airtight seal.
Install the vertical termination cap.
Light the unit and ensure proper operation.
THE  USE  OF  ANY  EXISTING  CHIMNEY  AS  AN  AIR  INTAKE 
IS  NOT  COVERED  UNDER  THE  ANSI  Z21.88-2002  CSA 
2.33a-2002  TEST  METHODS  AND  THE  RESULTING  ITS/WH 
PRODUCT  CERTIFICATION.  THE  CODE  AUTHORITY  HAVING 
JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING 
WITH THIS INSTALLATION METHOD.
Figure 36: Assembly of Venting into a Class 
‘A’ Chimney.
Initial Installation
QUALIFIED INSTALLERS ONLY
26