Dimplex DS7425DLX User Manual

Page of 12
12 
 
 
 
 
 
 
 
 
 
 
 
 
www.dimplex.com
PROBLEM
CAUSE
SOLUTION
Heater Continued
Heater is not turning on
Improper operation
Refer to Operation Section
Defective heater assembly
Replace heater assembly
Defective heater on/off switch
Replace heater on/off switch
Heater is turning off after a 
couple of minutes of operation
Build up of dirt/dust in heater assembly
Clean out heater assembly
Defective Motor
Replace Motor
Heater emits an odor
Normal Operation
Normal operation is when the heater emits an odor 
for a brief period after the heater is initially turned on.  
The heater is burning off any dust accumulated during 
manufacturing or operation.
Defective heater assembly
Replace heater assembly
Heater fan turns on but heater 
lacks heat
Improper operation
Refer to Operation Section
Defective thermostat
Replace thermostat
Loose wiring
Trace wiring in unit
Defective heater assembly
Replace heater assembly
Heating element is glowing red
Normal Operation
Small glowing sections of the element are considered 
normal.
Defective heater assembly
If larger glowing sections are causing the heater to trip 
the thermal cutout, unplug unit, discontinue use and 
replace heater assembly.
Heater fan runs continuously
Loose wiring
Trace wiring in unit
Defective heater on/off switch
Replace heater on/off switch
Defective heater assembly
Replace heater assembly
Defective thermostat
Replace thermostat
Noise
Excessive noise with the heater 
on
Dirty blower assembly
Clean blower assembly
Defective blower assembly
Replace heater assembly
Grinding or excessive noise with 
the heater off
Moving flame rod hitting or rubbing 
against internal components
Ensure rod is straight and mounted properly in the 
bracket, spinning freely away from other components. 
Replace if necessary.
Defective flame motor
Replace flame motor