American Standard 3821.641 Series User Manual

Page of 4
M 9 6 8 1 8 8 E
On model with separate spray, place the SPRAY HOLDER (1)
into the appropriate mounting hole. Assemble the SPRAY
HOLDER WING NUT (2) onto the shank of SPRAY HOLDER (1)
from below and tighten. Do not use putty.
On model with spray through the ESCUTCHEON (3), place
SPRAY HOLDER (4) into the hole of ESCUTCHEON (3). Assemble
SPRAY HOLDER NUT (5) onto the shank of SPRAY HOLDER (4)
from below and tighten. Do not use putty.
For installation less spray cap off SPRAY HOSE CONNECTION
with PIPE CAP (6).
3
INSTALL SPRAY HOLDER
1
3
5
6
4
2
4
CONNECT HOSE SPRAY
3
4
1
2
Feed SPRAY HOSE (1) through SPRAY HOLDER (2) and attach
COUPLING NUT (3) of HOSE (1) to HOSE ADAPTOR (4) on valve
body. Tighten COUPLING NUT (3) firmly.
Carefully bend COPPER SUPPLIES to meet water supply
lines using the palms of the hands to avoid kinking.
Connect HOT water supply line to left tube, and COLD
water supply line to right tube using appropriate
connectors.
2
3
4
FERRULE
SPRAY HOSE
CONNECTION
HOT
COLD
MAKE WATER SUPPLY CONNECTIONS
Use 1/2" IPS FLEXIBLE SUPPLIES (3) or 3/8" O.D.
BULL-NOSE RISERS (4). Use adjustable wrench to tighten
connections. Do not over tighten. Be careful not to kink
copper supply when bending. Use tubing cutter to cut to
proper length.
NOTE: FLEXIBLE SUPPLIES HAVE TO BE PURCHASED SEPARATELY
COPPER SUPPLIES
TUBES