American Standard 3821.641 Series User Manual

Page of 4
M 9 6 8 1 8 8 E
5
TEST INSTALLED FAUCET
Move HANDLE down into "off" position and remove AERATOR.
Turn on water supplies and check connections for leaks
.
Operate HANDLE up and down, left and right to flush water
lines thoroughly.
For faucet with spray, direct SPRAY HEAD into sink and
activate SPRAY. Check hose connections for leaks.
Move HANDLE down to "off" position and replace AERATOR.
AERATOR
CHECK CONNECTIONS
FOR LEAKS
Spout leakage. If fitting leaks above or below SPOUT HUB remove SPOUT as follows
and check SPOUT O-RINGS and SPACER O-RINGS.
Loosen SET SCREW (1). Pull HANDLE (2) off valve stem.
Remove CAP (3) and and RETAINER (4). Loosen CARTRIDGE SCREWS (5) and
remove CARTRIDGE (6).
Pull off SPACER (7) and O-RINGS (8).
Remove SPOUT (11) by pulling up gently while moving SPOUT (11) side to side.
Check both SPOUT O-RINGS (10). Replace if necessary.
On models with SPRAYS, DIVERTER (9) can be cleaned by pulling
DIVERTER (9) out of the MANIFOLD (12). Clean DIVERTER (9) and
MANIFOLD (12). Push DIVERTER (9) back into MANIFOLD (12).
Reverse procedure to reinstall SPOUT, CARTRIDGE and HANDLE.
Loosen HANDLE SCREW (1) and remove HANDLE (2).
Remove ESCUTCHEON CAP (3). unscrew the three CARTRIDGE SCREWS (5).
Clean inlets of CARTRIDGE (6) and MANIFOLD (12).
Reassemble CARTRIDGE (6), alternately tightening SCREWS (5). Replace CAP (3) and HANDLE (2). Check flow.
SERVICE
6
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
Reduced flow. If the flow gradually reduces over a number of months, the AERATOR
may have collected debris. To clean, remove AERATOR and rinse with water and
remove any debris. Turn on faucet to wash any debris out of the faucet. Thread
AERATOR back into spout. Operate faucet.
2
1
6
10
12
11
3
4
5
7
9
8
Remove as much surface dirt and film using clear 
water and soft cotton cloth (as described).
     Use any of the following to remove tough surface 
     film and build-up:
     Mild liquid detergents
     Clear ammonia free liquid glass cleaners
     Non-acidic, non-abrasive gentle liquid or fully
     dissolved powder cleansers mixed according to
     manufacturers directions.
     Non-abrasive liquid polishers
Once clean, rinse faucet again with clear water to 
thoroughly remove cleaner or polish and 
and blot dry
with a cotton cloth.  
 
To keep your new faucet looking new, please follow
these simple care instructions:
DO:     Simply rinse the faucet clean with clear water.
           Dry the faucet with a soft cotton cloth.
DO NOT:
           Do not use any abrasive cleaners, cloths, or 
           paper towels.
           Do not use any cleaning agents containing acids, 
polish abrasives, or harsh cleaners or soaps.
Regular and routine cleaning will reduce the need for
heavy cleaning and polishing. If heavy cleaning is
required, the following procedures are recommended:
7
Failure to follow these care instructions may
damage the faucet's finish.
CARE INSTRUCTIONS
H A N D L E
S P R A Y
A E R A T O R
S P O U T
H U B