USE  
SCRUBBER SETUP 
 
   
            NOTE 
                 
Read operators manual thoroughly prior to operating or servicing this machine!!!
 
 
a) PRE-OPERATION CHECKS 
1.  Sweep the outside of the machine.   
2.  Make sure the voltage of machine conform to local voltage.    (220-240V) 
3.  Check that squeegee is properly installed. 
4.  Check that brush / pad is properly installed. 
5.  Bumper doesn’t touch the floor directly. The gap between the bumper and the floor surface can 
be adjusted by adjusting sliding plate.   
6.  The forward speed of machine can be controlled by turning the butterfly nut. Turn the nut 
clockwise to speed up machine. Or turn the nut anticlockwise to slow down machine.   
7.  Make sure the working surface can support the machine weight, the gradient of the floor can’t 
exceed the limit that machine allow. 
 
b) INSTALLING PAD DRIVER OR BRUSH 
1. Unplug machine. 
2.  Tilt the machine backwards, line up the drive pulley hub with the hole of brush or pad driver, 
make sure the three blocks are fitted into the three slots of drive pulley.   
3.  If a pad driver is being used, the appropriate pad should be attached to the pad driver first.   
4.  Plug power cord into a grounded outlet, switch on the brush motor and then pull the operating 
triggers gently to mount the pad driver or brush automatically.   
 
                                                                     
                                                                                                                                                                       
   
 
 
 
 
 
 
 
c) INSTALLING THE SQUEEGEE 
1.  Loosen the two knobs on the squeegee and slide the squeegee into the slots at the rear of the 
squeegee bracket. (the wheels on the squeegee point to the back) 
2.    Tighten the knobs securely.
 
 
    d)
 FILLING THE SOLUTION TANK
 
1.  The fill port is located at the rear of machine.   
2.  Fill solution tank with water. (water temperature should not exceed 50℃) The clear tube in the 
back left of the machine has gallon markers to help determine the water level in the solution 
tank 
WARNING!  
             
Do not put any flammable materials into solution tank. This can cause an 
explosion or a fire.    Only use recommended cleaning chemicals. Contact your 
janitorial supply distributor for recommendations on proper chemicals. 
 
 