Sony R500PC User Manual

Page of 58
19
MZ-R500/R500PC
• Setting method of power supply manual adjustment
1. Make sure that the power supply voltage is 3V.
2. Set the test mode (see page 12).
3. Press the
.
or 
[VOL--]
 key to activate the overall adjustment
mode.
4. Press the 
[END SEARCH]
 key. (the 
[END SEARCH]
 key causes
the item number to be switched to 762.)
• Adjustment method of Vc PWM Duty (L)
(item number: 762)
1. Press the 
[ENTER]
 key and set the address & adjusted value
display (see page 14).
2. Connect a digital voltmeter to the TP902 (VC) on the MAIN
board, and adjust 
[VOL +]
 key (voltage up) or 
[VOL --]
 key
(voltage down) so that the voltage becomes 2.40 ± 0.01 V.
3. Press the
X
key to write the adjusted value.
(The item number changes to 763 when
X
key is pressed)
Adjustment and Connection Location: MAIN board
(see page 21)
• Adjustment method of Vc PWM Duty (H)
(item number: 763)
1. Press the 
[ENTER]
 key and change the LCD display.
3) Press the
X
key to write the adjusted value.
4) Select the manual mode of the test mode, and set item number
862 (see page 13).
5) Adjust with the 
[VOL+]
 key (adjusted value up) or 
[VOL--]
key (adjusted value down) so that the adjusted value becomes
01.
6) Press the
X
key to write the adjusted value.
7) Select the manual mode of the test mode, and set item number
871 (see page 13).
8) Adjust with the 
[VOL+]
 key (adjusted value up) or 
[VOL--]
key (adjusted value down) so that the adjusted value becomes
20.
9) Press the
X
key to write the adjusted value.
10) Select the manual mode of the test mode, and set item number
872 (see page 13).
11) Adjust with the 
[VOL+]
 key (adjusted value up) or 
[VOL--]
key (adjusted value down) so that the adjusted value becomes
39.
12) Press the
X
key to write the adjusted value.
5-5. Power Supply Manual Adjustment
• Adjustment sequence
Adjustment must be done with the following steps.
This set LCD display
   8 6 2
V1dat
2.    Vc PWM Duty (H) adjustment (item number 763)
3.    Vl PWM Duty adjustment (item number 764)
1.    Vc PWM Duty (L) adjustment (item number 762)
digital
voltmeter
MAIN board
TP902(VC)
TP910(GND)
: Address
01
: Adjusted value 
This set LCD display
   8 6 2
S01
This set LCD display
   8 7 1
V5num
: Address 
20
: Adjusted value 
This set LCD display
   8 7 1
S20
This set LCD display
   8 7 2
V5dat
: Address 
39
: Adjusted value 
This set LCD display
   8 7 2
S39
This set LCD display
   0 0 0
Assy11
This set LCD display
   7 6 2
Vc1PWM
This set LCD display
   7 6 2
 AD
: Adjusted value
This set LCD display
   7 6 3
VchPWM
This set LCD display
   7 6 3
 AD
: Adjusted value