MZ-R500/R500PC
3. Adjust with
[VOL +]
,
[VOL --]
key so that the adjusted value
(hexadecimal value) becomes the ambient temperature.
(Initial value: 14h = 20
(Initial value: 14h = 20
°
C, Adjusting range: 80h to 7fh (–128
°
C to +127
°
C)
4. Press the
X
key to write the adjusted value.
5-7. Laser Power Check
Connection :
Checking Method :
1. Select the manual mode of test mode (see page 13), and set the
1. Select the manual mode of test mode (see page 13), and set the
laser power adjusting mode (item number 010).
2. Press the
.
key continuously until the optical pick-up
moves to the most inward track.
3. Open the cover and set the laser power meter on the objective
lens of the optical pick-up.
4. Press the
N
key, and set the laser MO read adjustment mode
(item number 011).
5. Press the
[ENTER]
key and set the address & adjusted value
display (See page 14).
6. Check that the laser power meter reading is 0.81 ± 0.08 mW.
7. Check that the voltage both ends (TP (+) and TP (–)) of resis-
7. Check that the voltage both ends (TP (+) and TP (–)) of resis-
tor R501 at this time is below 44 mV.
2. Connect a digital voltmeter to the TP902 (VC) on the MAIN
board, and adjust
[VOL +]
key (voltage up) or
[VOL --]
key
(voltage down) so that the voltage becomes 2.75 ± 0.01 V.
3. Press the
X
key to write the adjusted value.
(The item number changes to 764 when
X
key is pressed)
Adjustment and Connection Location: MAIN board
(see page 21)
• Adjustment method of Vl PWM Duty
(item number: 764)
1. Press the
[ENTER]
key and change the LCD display.
2. Connect a digital voltmeter to the TP901 (VL) on the MAIN
board, and adjust
[VOL +]
key (voltage up) or
[VOL --]
key
(voltage down) so that the voltage becomes 2.30 ± 0.01 V.
3. When press the
X
key to write the adjusted value, LCD dis-
plays as follows and power supply manual adjustment has com-
pleted.
pleted.
Adjustment and Connection Location: MAIN board
5-6. Temperature Correction
• Adjustment Method of temperature correction
1. Select the manual mode of test mode, and set the mode num-
ber 014 (see page 13).
2. Measure the ambient temperature.
digital
voltmeter
MAIN board
TP902(VC)
TP910(GND)
This set LCD display
7 6 4
V1 PWM
This set LCD display
7 6 4
AD
: Adjusted value
digital
voltmeter
MAIN board
TP901(VL)
TP910(GND)
This set LCD display
0 0 0
ADJ OK
This set LCD display
0 1 4
SetTmp
: Address
14
: Adjusted value
This set LCD display
0 1 4
S14
digital voltmeter
MAIN board
TP(+)
TP(–)
TP(–)
laser
power meter
Optical pick-up
objective lens
objective lens
This set LCD display
0 1 0
Laser
This set LCD display
0 1 1
LrefPw
This set LCD display
0 1 1
###S
###
: Address
: Adjusted value