7.2.5  Replacing filter element 
 
During the follow-
ing work, ensure 
that dust is not un-
necessarily spread 
around. Wear a P2 
(2).
3. Place the protective filter 
bag
1)
 over the filter element 
(3).
4. Carefully remove the filter 
element and close the pro-
tective filter bag with a knot.
5. Clean the filter seal (4). 
Check it for damage and 
replace it if necessary.
6.  Fit a new filter element.
7.  Check that the float (5) works 
properly. When the filter hold-
er is turned, the float inside 
must move about easily.
8.  Fit the filter holder and turn it 
clockwise to secure it firmly.
9. Dispose of the used filter 
element in accordance with 
legal regulations.
Never use the vacuum cleaner 
without a filter.
breathing mask.
1. Open the retaining clamps 
and remove the upper sec-
1) 
Accessory. Order No. shown in section 9.5.
5.  Tip out the collected dirt.
6.  Place the empty tank in the 
frame and close the locks 
(4).
7.  Dispose of the dirt in accord-
ance with legal regulations.
3
5
1
2
1
2
4
tion of the cleaner from the 
dirt tank. Lay the upper sec-
tion of the cleaner down with 
the filter element facing up-
wards.
2. Turn the filter holder anti-
clockwise (1) and remove it 
7.2.6  Replacing the filter for 
air supply to motor
 
During the following 
work, ensure that 
dust is not unneces-
sarily spread around. 
Wear a P2 breathing 
mask.
1
2
3
4
1. Loosen screws.
2. Remove the filter cassette 
(1).
3.  Remove the frame (2) with 
filter felt (3) from the filter 
holder (4).
4.  Insert new filter felt and fix it 
with frame.
5.  Attach the filter cassette and 
insert the screw again.
6.  Dispose of used filter felt in 
accordance with the regula-
tions.