Fault
Cause
Remedy
‡ Motor does not start
> Fuse of the mains socket has 
blown.
Connect mains fuse.
> Overload protection switch 
has tripped.
Switch off the vacuum cleaner 
and allow it to cool for approx. 
5 minutes. If the cleaner can-
not be started again, contact 
the Nilfisk-Alto service depart-
ment.
‡ Motor does not run in auto-
matic mode
> Power tool is defective or not 
connected properly.
Check that the power tool 
works or that the plug is in-
serted correctly.
> The power rating of the elec-
trical tool is too low.
Note that minimum power rat-
ing is P>40W
‡ The acoustic warning 
sounds. (Reduced suction 
power)
> Suction power selected with 
suction power control is too 
low.
Set suction power in accord-
ance with section 4.2.3. „Set-
ting suction power“.
> Hose diameter and switch 
position do not correspond.
Set correct switch position for 
hose diameter.
> Clogged suction hose/nozzle.
Clean suction hose/nozzle
> Filter bag is full.
See section 7.2.2 „Replacing 
filter bag“.
> Filter element is clogged.
See section 4.5/4.6 „Cleaning 
filter element“ and 7.2.5/7.2.6 
„Replacing filter element“.
‡ No suction power during 
wet cleaning
> Tank is full. (Float does not 
close the suction opening).
Switch off the cleaner. Empty 
the tank.
‡ The vacuum cleaner 
switches off during wet 
cleaning
> Tank is full.
Switch off the cleaner. Empty 
the tank.
‡ Voltage fluctuations
> Impedance of power supply is 
too high.
Connect the cleaner to an-
other socket closer to the fuse 
box. Voltage fluctuations over 
7% should not occur if the im-
pedance at the transfer point 
is 
≤ 0.15 Ω .