BATTERY CHECK/SETTING ON A NEW 
MACHINE
The machine requires one 24V battery, or four 6V 
batteries in serial connection.
The machine can be supplied in one of the following 
modes:
a)
Batteries already installed and ready to be used.
1. Lift the hood (13, Fig. C) and secure it with the rod 
(16, Fig. V). 
Check that the batteries are connected to the 
machine through the related connector (4, Fig. V).
2. Disengage the support rod an lower the hood and 
ensure that it is correctly closed.
3. Insert the ignition key (18, Fig. B) in the control 
panel and turn it to “I” position (without activating 
the forward/reverse gear pedal 20, Fig. B).
If the green warning light (9, Fig. B) turns on, the 
battery is ready to be used.
If the yellow or red warning light (8 or 7, Fig. B) 
turns on, it is necessary to charge the battery (see 
procedure in Maintenance chapter).
b)
Batteries installed on the machine but dry, that is 
without electrolyte.
1. Lift the hood (13, Fig. C) and secure it with the rod 
(16, Fig. V).
2. Remove the battery caps (3, Fig. V).
3. Fill the cells (or each element) of the batteries with 
sulphuric acid for batteries (density from 1.27 to 
1.29 Kg at 25°C) in accordance with the 
instructions given in the Battery User's Manual.
The correct quantity of sulphuric acid is indicated 
in the Battery Manual.
Let the battery rest and fill in with sulphuric acid in 
accordance with the instructions specified in the 
Battery manual.
4. Charge the batteries (see the relevant procedure 
in the Maintenance chapter).
c)
Without battery
1. Buy appropriate batteries (see the Technical 
Characteristics paragraph).
For the battery choice and installation, apply to 
qualified battery retailers.
2. Install the batteries and set the battery type (WET 
or GEL) on the machine (see the following 
paragraph).
3. Charge the batteries (see the relevant procedure 
in the Maintenance chapter).
WARNING!
On some points of the machine there are 
some adhesive plates indicating:
DANGER
WARNING
CAUTION
NOTE
WARNING!
Be extremely careful when working with 
sulphuric acid, as it is corrosive. If it comes 
in contact with skin or eyes, rinse 
thoroughly with water and call a physician. 
Batteries have to be filled up in a properly 
ventilated area. Use protective gloves.