MODEL 5081-P pH/ORP
SECTION 1.0
DESCRIPTION AND SPECIFICATIONS
1.2  SPECIFICATIONS
1.2.1 GENERAL SPECIFICATIONS
Housing: Cast aluminum with epoxy coating. Type 4X
(IP65). Neoprene O-ring cover seals.
Dimensions: 160.5 mm x 175.3 mm x 161.3 mm (6.3 in.
x 6.9 in. x 6.4 in.) See drawing.
Conduit Openings: ¾-in. FNPT
Ambient Temperature: -4 to 149°F (-20 to 65°C)
Storage Temperature: -22 to 176°F (-30 to 80°C)
Relative Humidity: 0 to 95% (non-condensing)
weight/Shipping weight: 10 lb/10 lb (4.5/5.0 kg)
Display: Two-line LCd; first line shows process variable
(pH, ORP, conductivity, % concentration, oxygen,
ozone, or chlorine), second line shows process tem-
perature and output current. For pH/chlorine combina-
tion, the second line can be toggled to show pH. Fault
and warning messages, when triggered, alternate with
temperature and output readings.
First line: 7 segment LCd, 0.8 in. (20 mm) high.
Second line: 7 segment LCd, 0.3 in. (7mm) high.
display board can be rotated 90 degrees clockwise or
counterclockwise.
during calibration and programming, messages and
prompts appear in the second line.
Temperature resolution: 0.1°C
Hazardous Location Approval: For details, see specifi-
cations for the measurement of interest.
RFI/EMI: EN-61326
Digital Communications: 
HART —
Power & Load Requirements:
Supply voltage at the transmitter terminals should be at
least 12 Vdc. Power supply voltage should cover the volt-
age drop on the cable plus the external load resistor
required for HART communications (250 W minimum).
Minimum power supply voltage is 12 Vdc. Maximum
power supply voltage is 42.4 Vdc (30 Vdc for intrinsically
safe operation). The graph shows the supply voltage
required to maintain 12 Vdc (upper line) and 30 Vdc
(lower line) at the transmitter terminals when the current is
22 mA.
Analog Output: Two-wire, 4-20 mA output with superim-
posed HART digital signal. Fully scalable over the
operating range of the sensor.
Output accuracy: ±0.05 mA
F
OUNDATION
FIELDBUS —
Power & Load Requirements: A power supply voltage of
9-32 Vdc at 22 mA is required.
1.2.2 FUNCTIONAL SPECIFICATIONS
pH Range:  0 to 14
ORP Range: -1400 to +1400mV
Calibrations/standardization: The automatic buffer
recognition uses stored buffer values and their tem-
perature curves for the most common buffer standards
available worldwide. The transmitter also performs a
stabilization check on the sensor in each buffer.
A manual two-point calibration is made by immersing
the sensor in two different buffer solutions and enter-
ing the pH values. The microprocessor automatically
calculates the slope which is used for self-diagnostics.
An error message will be displayed if the pH sensor is
faulty. This slope can be read on the display and/or
manually adjusted if desired.
An on-line one-point process standardization is
accomplished by entering the pH or ORP value of a
grab sample as measured by a lab reference.
Preamplifier Location: A preamplifier must be used to
convert the high impedance pH electrode signal to a
low impedance signal for transmitter use. The integral
preamplifier of the Model 5081-P may be used when
the sensor to transmitter distance is less than 15 ft
(4.5 m). Locate the preamplifier in the sensor or junc-
tion box for longer distances.
Automatic Temperature Compensation: External 3 or 4
wire Pt 100 RTd or Pt 1000 RTd located in the sen-
sor, compensates the pH reading for temperature fluc-
tuations. Compensation covers the range -15 to 130°C
(5 to 270°F). Manual temperature compensation is
also selectable.
HART option
Sira MC070112/00