Sennheiser SK 500 G3 User Manual

Page of 42
33
Specifications
Specifications
RF characteristics 
Modulation
wideband FM
Frequency ranges
516–558, 566–608, 
626–668, 734–776, 
780–822, 823–865 MHz 
(A–E, G, see page 3)
Transmission frequencies
1,680 frequencies, tune-
able in steps of 25 kHz
20 frequency banks, each 
with up to 32 factory-
preset channels
6 frequency banks, each 
with up to 32 user 
programmable channels
Switching bandwidth
42 MHz
Nominal/peak deviation
± 24 kHz/± 48 kHz
Frequency stability
≤ ±15 ppm
RF output power at 50 
Ω, 
switchable
typ. 10 mW (low)
typ. 30 mW (standard)
Pilot tone squelch
can be switched off
AF characteristics 
Compander system
Sennheiser 
HDX
AF frequency response
microphone: 
80–18,000 Hz
line: 25–18,000 Hz
Signal-to-noise ratio
(1 mV, peak deviation) 
≥ 115 dBA
THD 
≤ 0.9%
Max. input voltage
microphone/line
3 V
rms
Input impedance 
microphone/line
40 k
Ω, unbalanced/1 MΩ
Input capacitance 
switchable
Adjustment range of input 
sensitivity
60 dB, adjustable in 3-dB 
steps
Overall device 
Temperature range
−10°C to +55°C
Power supply
2 AA size batteries, 1.5 V 
or BA 2015 accupack
Nominal voltage
2.4 V 
Current consumption:
at nominal voltage
typ. 180 mA (30 mW)
with switched-off 
transmitter
≤ 25 μA