Bradford-White Corp E32-80R User Manual
Instructions for Conversion of Commercial Electric Models
8
Phase Conversion Only kits
Table 2. Phase Conversion Kits.
6KW
9KW
12KW
Volts
Conversion
Kit
Volts
Conversion
Kit
Volts
Conversion
Kit
208 265-45246-13 208 265-45246-14 208 265-45246-15
240 265-45246-07 240 265-45246-08 240 265-45246-09
480 265-45246-01 480 265-45246-02 480 265-45246-03
240 265-45246-07 240 265-45246-08 240 265-45246-09
480 265-45246-01 480 265-45246-02 480 265-45246-03
13.5KW
15KW
18KW
Volts
Conversion
Kit
Volts
Conversion
Kit
Volts
Conversion
Kit
208 265-45246-16 208 265-45246-17 208 265-45246-18
240 265-45246-10 240 265-45246-11 240 265-45246-12
480 265-45246-04 480 265-45246-05 480 265-45246-06
240 265-45246-10 240 265-45246-11 240 265-45246-12
480 265-45246-04 480 265-45246-05 480 265-45246-06
WARNING
Recheck and inspect to make certain all components involved in the
conversion are correct and secure.
conversion are correct and secure.
Recheck all of the electrical wiring changes made against the wiring diagram requirements for accuracy.
Check to insure all of the electrical connections are tightly secured and the electrical wire routings are
orderly.
Special attention should be given to the electrical heating elements. The wattage and voltage rating of the
element is marked on the element itself. Confirm the marking agrees with the intended conversion.
Additionally, the element wattage can be verified by checking the electrical resistance (ohms of resistance)
with an Ohm Meter. This should be done initially before connecting the element to the circuit. The element
resistance should be plus or minus 5 percent of the following values:
Check to insure all of the electrical connections are tightly secured and the electrical wire routings are
orderly.
Special attention should be given to the electrical heating elements. The wattage and voltage rating of the
element is marked on the element itself. Confirm the marking agrees with the intended conversion.
Additionally, the element wattage can be verified by checking the electrical resistance (ohms of resistance)
with an Ohm Meter. This should be done initially before connecting the element to the circuit. The element
resistance should be plus or minus 5 percent of the following values:
Table 3. Ohms of Electrical Resistance.
Voltage Rating of the Element
Element
Wattage
Wattage
208 volts
240 volts
480 volts
2000 21.6
28.8
115.2
3000
14.4 19.2 76.8
4000
10.8 14.4 57.6
4500 9.6
12.8
51.2
5000 8.7
11.5
46.1
6000 7.2
9.6
38.4